Quantification of ciprofloxacin in pharmaceutical products from various brands using FT-NIR: A comparative investigation of PLS and MCR-ALS

M Alaoui Mansouri, M Kharbach, M El Maouardi, I Barra, A Bouklouze

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2023-12 · 303 · 123268

DOI: 10.1016/j.saa.2023.123268 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2023-12. Verfasst von M Alaoui Mansouri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nano and Molecular Systems Research Unit, University of Oulu, FI-90014 Oulu, Finland; Bio-Pharmaceutical and Toxicological Analysis Research Team, La…. Hauptthemen laut MEDLINE: Excipients, Chemometrics. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to quantify ciprofloxacin in commercial tablets with varying excipient compositions using Fourier Transform Near-Infrared Spectroscopy (FT-NIR) and chemometric models: Partial Least Squares (PLS) and Multivariate Curve Resolution - Alternating Least Squares (MCR-ALS). Matrix variation, arising from differences in excipient compositions among the tablets, can impact quantification accuracy. We discuss this phenomenon, emphasizing potential issues introduced by varying certain excipients and its importance in reliable ciprofloxacin quantification. We evaluated the performance of PLS and MCR-ALS models independently on two sets of tablets, each containing the same drug substance but different excipients. The statistical results revealed promising results with PLS prediction error of 0.38% w/w of the first set and 0.47% w/w of the second set, while MCR-ALS achieved prediction errors of 0.67% w/w of the first set and 1.76% w/w of the second set. To address the challenge of matrix variation, we developed single models for PLS and MCR-ALS using a dataset combining both first and second sets. The PLS single model demonstrated a prediction error of 4.3% w/w and a relative error of 6.41% w/w, while the MCR-ALS single model showed a prediction error of 1.88% w/w and a relative error of 1.29% w/w. We then assessed the performance of the single PLS and MCR-ALS models developed based on the combination of the first and the second set in quantifying ciprofloxacin in various commercial tablet brands containing new excipients. The PLS model achieved a prediction error ranging between 6.2% w/w and 8.39% w/w, with relative errors varied between 8.53% w/w and 12.82% w/w. On the other hand, the MCR-ALS model had a prediction error between 1.11% w/w and 2.66% w/w, and the relative errors ranging from 0.8% to 1.74% w/w.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ExcipientsChemometricsLeast-Squares AnalysisCiprofloxacinSpectroscopy, Fourier Transform Infrared

Stichwörter der Autor:innen

CiprofloxacinFT-NIRMCR-ALSMatrix effectPLS

Substanzen

ExcipientsCiprofloxacin

Autor:innen und Institutionen

  • Nano and Molecular Systems Research Unit, University of Oulu, FI-90014 Oulu, Finland; Bio-Pharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharm…
  • Bio-Pharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat, Morocco; Research Unit of Mathematical Sciences, Un…
  • Bio-Pharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat, Morocco.
  • Bio-Pharmaceutical and Toxicological Analysis Research Team, Laboratory of Pharmacology and Toxicology, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat, Morocco; Center of Excellence in Soil and Fertilize…

Zitieren

APA

Alaoui Mansouri, M., Kharbach, M., El Maouardi, M., Barra, I., & Bouklouze, A. (2023). Quantification of ciprofloxacin in pharmaceutical products from various brands using FT-NIR: A comparative investigation of PLS and MCR-ALS. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 303, 123268. https://doi.org/10.1016/j.saa.2023.123268

Vancouver

Alaoui Mansouri M, Kharbach M, El Maouardi M, Barra I, Bouklouze A. Quantification of ciprofloxacin in pharmaceutical products from various brands using FT-NIR: A comparative investigation of PLS and MCR-ALS. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2023;303:123268. doi:10.1016/j.saa.2023.123268

BibTeX
@article{AlaouiMansouri2023,
  author = {Alaoui Mansouri, M and Kharbach, M and El Maouardi, M and Barra, I and Bouklouze, A},
  title = {Quantification of ciprofloxacin in pharmaceutical products from various brands using FT-NIR: A comparative investigation of PLS and MCR-ALS},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2023},
  volume = {303},
  pages = {123268},
  doi = {10.1016/j.saa.2023.123268}
}
Kostenlos starten →