A determination method for clenbuterol residue in pork based on optimal particle size gold colloid using SERS

Qinghui Guo, Yankun Peng, Kuanglin Chao, Jianwei Qin, Yahui Chen, Tianzhen Yin

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2023-12 · 302 · 123097

DOI: 10.1016/j.saa.2023.123097 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2023-12. Verfasst von Qinghui Guo und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Engineering, National R&D Center for Agro-processing Equipment, China Agricultural University, Beijing 100083, China. Hauptthemen laut MEDLINE: Clenbuterol, Pork Meat, Red Meat. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Clenbuterol is often used as a feed additive to increase the percentage of lean meat in livestock. Meat containing clenbuterol can cause many illnesses and even death for people. In this paper, the particle growth method was used to prepare gold colloids of different sizes, and the enhanced effectiveness of gold colloids of different sizes on clenbuterol in pork was investigated. The results showed that the gold colloid with the best enhanced effectiveness for clenbuterol had a particle size of approximately 90 nm. Second, a sample collection component was designed to detect clenbuterol from bottom to top, solving the problem of poor reproducibility of Surface-enhanced Raman scattering (SERS) detection caused by different droplet sizes and shapes. Then, the influence of different volumes of samples and concentrations of aggregating compounds on the enhanced effectiveness was optimized. The results showed that, based on the sample collection components designed in this article, 5 µL of enhanced substrate, 7.5 µL of clenbuterol and 3 µL of 1 mol/L mixed detection of NaCl solution had the best enhanced performance. Finally, 88 pork samples (0.5, 1, 1.5,…, 10, 12, 14 µg/g) with different concentrations were divided into correction sets and prediction sets in a ratio of 3:1. Unary linear regression models were established between the concentration of clenbuterol residue in the pork and the intensity of the bands at 390, 648, 1259, 1472, and 1601 cm-1. The results showed that the unary linear regression models at 390, 648, and 1259 cm-1 had lower root mean square errors than those at 1472 and 1601 cm-1. The intensity of the three bands and the concentration of clenbuterol residue in the pork were selected to establish a multiple linear regression model, and the concentration of clenbuterol residue in the pork was predicted. The results showed that the determination coefficients (R2) of the correction set and the prediction set were 0.99 and 0.99, respectively. The root mean square errors (RMSE) of the correction set and the prediction set were 0.169 and 0.184, respectively. The detection limit of clenbuterol in pork by this method is 42 ng/g, which can realize the crude screening of pork containing clenbuterol in the market.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ClenbuterolPork MeatRed MeatAnimalsSwineHumansGold ColloidReproducibility of ResultsParticle SizeGoldColloids

Stichwörter der Autor:innen

ClenbuterolOptimal particle sizeSample collection componentSurface-enhanced Raman scattering

Substanzen

ClenbuterolGold ColloidGoldColloids

Autor:innen und Institutionen

  • College of Engineering, National R&D Center for Agro-processing Equipment, China Agricultural University, Beijing 100083, China.
  • College of Engineering, National R&D Center for Agro-processing Equipment, China Agricultural University, Beijing 100083, China. Electronic address: ypeng@cau.edu.cn.
  • USDA/ARS Environmental Microbial and Food Safety Laboratory, Beltsville Agricultural Research Center, 10300 Baltimore Ave., Beltsville, MD 20705, USA.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Guo, Q., Peng, Y., Chao, K., Qin, J., Chen, Y., & Yin, T. (2023). A determination method for clenbuterol residue in pork based on optimal particle size gold colloid using SERS. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 302, 123097. https://doi.org/10.1016/j.saa.2023.123097

Vancouver

Guo Q, Peng Y, Chao K, Qin J, Chen Y, Yin T. A determination method for clenbuterol residue in pork based on optimal particle size gold colloid using SERS. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2023;302:123097. doi:10.1016/j.saa.2023.123097

BibTeX
@article{Guo2023,
  author = {Guo, Qinghui and Peng, Yankun and Chao, Kuanglin and Qin, Jianwei and Chen, Yahui and Yin, Tianzhen},
  title = {A determination method for clenbuterol residue in pork based on optimal particle size gold colloid using SERS},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2023},
  volume = {302},
  pages = {123097},
  doi = {10.1016/j.saa.2023.123097}
}