Carbon dots electrochemically prepared from dopamine and epigallocatechin gallate for hypochlorite detection with high selectivity via a dynamic quenching mechanism
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2023
DOI: 10.1016/j.saa.2023.122947 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2023. Verfasst von Tiantian Long und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Health Management Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China; National Engineering Laboratory for…. Hauptthemen laut MEDLINE: Quantum Dots. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben.
Abstract (Originalsprache)
Monitoring hypochlorite levels in water is of great importance because of its high toxicity and wide applications as water disinfectants. In this manuscript, carbon dot (CD) was electrochemically prepared by using dopamine and epigallocatechin gallate (molar ratio 1:1) as the carbon source for efficient hypochlorite determination. By electrolyzing the solution at 10 V for 12 min with PBS as an electrolyte, dopamine would react with epigallocatechin at the anode, and through polymerization, dehydration, and carbonization, strong blue-fluorescent CDs were obtained. CDs were characterized by UV-Vis spectroscopy, fluorescence spectroscopy, high-resolution transmission electron microscopy, FT-IR, etc. These CDs have an excitation wavelength at 372 nm and an emission wavelength at 462 nm, owing an average particle size of 5.5 nm. The presence of hypochlorites can quench the fluorescence of CDs, and its reduction in intensity is linear with hypochlorite concentration over the range of 0.5-50 μM, ΔF/F0 = 0.0056 + 0.0194CClO-, R2=0.997. The detection limit achieved 0.23 μM (S/N = 3). The mechanism for fluorescence quenching is via a dynamic process. Different from many other fluorescence methods based on the strong oxidizing ability of hypochlorites, our method shows strong selectivity toward hypochlorites over other oxidizing agents such as H2O2. The assay was validated by the detection of hypochlorites in water samples, with recoveries between 98.2% and 104.3%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The Health Management Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China; National Engineering Laboratory for Rice and By-products Further Processing, College of Food Science and…
- The Neurology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China.
- Department of Neurosurgery, The Second Affiliated Hospital of Nanchang University, Nanchang 330006, China.
- The Health Management Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China.
- Hunan Intellijoy Biotechnology Co., Ltd., Changsha, Hunan 410125, China.
- The Health Management Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China. Electronic address: Liulei19890403@163.com.
Zitieren
APA
Long, T., Hu, Z., Gao, Z., Luo, H., Li, H., Chen, Y., Liu, L., & Xu, D. (2023). Carbon dots electrochemically prepared from dopamine and epigallocatechin gallate for hypochlorite detection with high selectivity via a dynamic quenching mechanism. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2023.122947
Vancouver
Long T, Hu Z, Gao Z, Luo H, Li H, Chen Y, et al. Carbon dots electrochemically prepared from dopamine and epigallocatechin gallate for hypochlorite detection with high selectivity via a dynamic quenching mechanism. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2023. doi:10.1016/j.saa.2023.122947
BibTeX
@article{Long2023,
author = {Long, Tiantian and Hu, Zhongyang and Gao, Ziyun and Luo, Hongmei and Li, Hongchen and Chen, Yi and Liu, Lei and Xu, Dong},
title = {Carbon dots electrochemically prepared from dopamine and epigallocatechin gallate for hypochlorite detection with high selectivity via a dynamic quenching mechanism},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2023},
doi = {10.1016/j.saa.2023.122947}
}
EUVIMED