EUVIMEDEUVIMED entdecken
Crossref

A Zn-coordination polymer for the quantitative and selective colorimetric detection of residual tetracycline in aqueous solution and urine

Yatong Zhang, Ai Wang, Bing Huang, Xiaowei Liu, Ulli Englert, Liping Lu

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2023-06 · 294 · 122470

DOI: 10.1016/j.saa.2023.122470 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2023-06. Verfasst von Yatong Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Molecular Science, Key Laboratory of Chemical Biology and Molecular Engineering of the Education Ministry, Shanxi University, Taiyuan, S…. Hauptthemen laut MEDLINE: Colorimetry, Polymers. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Shanxi Scholarship Council of China, National Natural Science Foundation of China, Natural Science Foundation of Shanxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A one-step solvothermal synthesis provides a functional crystalline one-dimensional Zn-coordination polymer (Zn-CP) with excellent stability in aqueous solution over a wide range of temperature and pH. Zn-CP is a rapid, highly sensitive and selective sensor for detecting tetracycline (TC). Quantitative TC detection is based on the ratio of fluorescence intensities I530/I420, with a limit of detection (LOD) of 5.51 nM in aqueous solution and 47.17 nM in human urine. The characteristics of colorimetric TC sensing by Zn-CP are highly favorable for application because the color of Zn-CP changes in the visible part of the spectrum from blue-purple to yellow-green upon addition of TC. Conversion of these colors into an RGB signal is simply achieved with an app for the smart phone and provides LODs of 8.04 nM and 0.13 μM TC in water and urine, respectively. Our suggested sensing mechanisms assume that the fluorescence intensity of Zn-CP@TC at 530 nm is enhanced by energy transfer of Zn-CP to TC, while the fluorescence of Zn-CP at 420 nm is quenched by photoinduced electron transfer (PET) from TC to the organic ligand in Zn-CP. These fluorescence properties make Zn-CP a convenient, low-cost, rapid and green detection device for monitoring TC under physiological conditions and in aqueous media.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColorimetryPolymersHumansSpectrometry, FluorescenceFluorescent DyesTetracyclineAnti-Bacterial AgentsWaterZinc

Stichwörter der Autor:innen

Energy transferFluorescent test stripsPhotoinduced electron transferRatiometric fluorescence probeTetracycline detectionZn-coordination polymer

Substanzen

PolymersFluorescent DyesTetracyclineAnti-Bacterial AgentsWaterZinc

Autor:innen und Institutionen

  • Institute of Molecular Science, Key Laboratory of Chemical Biology and Molecular Engineering of the Education Ministry, Shanxi University, Taiyuan, Shanxi 030006, China.
  • Institute of Molecular Science, Key Laboratory of Chemical Biology and Molecular Engineering of the Education Ministry, Shanxi University, Taiyuan, Shanxi 030006, China. Electronic address: aiwang@sxu.edu.cn.
  • School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, Shanxi 030006, China.
  • Institute of Molecular Science, Key Laboratory of Chemical Biology and Molecular Engineering of the Education Ministry, Shanxi University, Taiyuan, Shanxi 030006, China; Institute of Inorganic Chemistry, RWTH Aachen Uni…
  • Institute of Molecular Science, Key Laboratory of Chemical Biology and Molecular Engineering of the Education Ministry, Shanxi University, Taiyuan, Shanxi 030006, China. Electronic address: luliping@sxu.edu.cn.

Förderung

  • Shanxi Scholarship Council of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Shanxi Province

Zitieren

APA

Zhang, Y., Wang, A., Huang, B., Liu, X., Englert, U., & Lu, L. (2023). A Zn-coordination polymer for the quantitative and selective colorimetric detection of residual tetracycline in aqueous solution and urine. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 294, 122470. https://doi.org/10.1016/j.saa.2023.122470

Vancouver

Zhang Y, Wang A, Huang B, Liu X, Englert U, Lu L. A Zn-coordination polymer for the quantitative and selective colorimetric detection of residual tetracycline in aqueous solution and urine. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2023;294:122470. doi:10.1016/j.saa.2023.122470

BibTeX
@article{Zhang2023,
  author = {Zhang, Yatong and Wang, Ai and Huang, Bing and Liu, Xiaowei and Englert, Ulli and Lu, Liping},
  title = {A Zn-coordination polymer for the quantitative and selective colorimetric detection of residual tetracycline in aqueous solution and urine},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2023},
  volume = {294},
  pages = {122470},
  doi = {10.1016/j.saa.2023.122470}
}
Kostenlos starten →