Power-Consistent State-Space Framework for One-Dimensional Cochlear Models
Results in Engineering · 2026-11 · 114075
DOI: 10.1016/j.rineng.2026.114075 ↗Kurz gefasst
Fachartikel in der Zeitschrift Results in Engineering, 2026-11. Verfasst von Zheyan Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
One-dimensional cochlear models are often calibrated using basilar membrane (BM) motion. This study examines numerical power consistency and internal mechanics among models with similar BM responses. A power-consistent state-space framework was developed from one-dimensional fluid-structure equations under a long-wave fluid approximation. Pressure–volume velocity and force–velocity pairs link fluid, partition, memory, active, and boundary powers within the same discrete formulation. Numerical closure and second-order spatial and fourth-order temporal convergence supported its numerical consistency. Power checks detected inconsistent force mapping and spatial integration weights even when BM magnitudes remained similar. A nonlinear delayed feedback implementation reproduced reference BM responses and closed the load power decomposition. To demonstrate controlled power-budget comparison, stable models with instantaneous velocity feedback or displacement feedback with first-order memory were used within a shared local two-degree-of-freedom structure, with BM peak gains of 32.97 and 32.07 dB relative to their common passive reference. At equal entrance pressure and the specified frequency, root-mean-square BM magnitude and phase differences were 0.468 dB and 2.386 ∘ . Complete-branch net power differed by 8.83%, whereas the second-structure/BM motion ratio remained close at the reference peak. The framework related this power difference to entrance power and mechanical losses. A longitudinally displaced-force example further illustrates power-conjugate mapping and explicit spatial power assignment. The framework provides a common basis for numerical auditing and for comparing internal mechanical quantities under controlled response conditions.
Zitieren
APA
Zhang, Z., Li, R., Dong, F., & Chen, K. (2026). Power-Consistent State-Space Framework for One-Dimensional Cochlear Models. Results in Engineering, 114075. https://doi.org/10.1016/j.rineng.2026.114075
Vancouver
Zhang Z, Li R, Dong F, Chen K. Power-Consistent State-Space Framework for One-Dimensional Cochlear Models. Results in Engineering. 2026:114075. doi:10.1016/j.rineng.2026.114075
BibTeX
@article{Zhang2026,
author = {Zhang, Zheyan and Li, Renwei and Dong, Fangyan and Chen, Kewei},
title = {Power-Consistent State-Space Framework for One-Dimensional Cochlear Models},
journal = {Results in Engineering},
year = {2026},
pages = {114075},
doi = {10.1016/j.rineng.2026.114075}
}
EUVIMED