EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

Bioinspired porous hip implants design: A systematic review of mechanical testing and additive manufacturing

Nik Nur Ain Azrin Abdullah, Muhammad Imam Ammarullah, Zatul Faqihah Mohd Salaha, Muhammad Hanif Baharuddin, Mohammed Rafiq Abdul Kadir, Muhammad Hanif Ramlee

Results in Engineering · 2025-03 · 25 · 103708

DOI: 10.1016/j.rineng.2024.103708 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Results in Engineering, 2025-03. Verfasst von Nik Nur Ain Azrin Abdullah und 5 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 112 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Technology Malaysia, Universitas Sriwijaya.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In clinical practice, the current medical device for total hip arthroplasty is made of a solid structural material. Unfortunately, stress shielding is developed as a result of the materials used in solid hip implants being stiffer than the surrounding bone, which can lead to hip implant failure. Therefore, many researchers devised a complex lattice structure embedded in the implant in order to address the aforementioned issues. However, the developed implant must undergo mechanical testing to ensure the model's reliability, as this approach can simulate the physiological conditions of human daily activities such as standing, walking, running, and leaping. In addition, the manufacturing method of the implant plays a significant role in ensuring that the procedure does not inhibit the mechanical properties and bone ingrowth of the model, as the porous lattice structure is extremely difficult to manufacture. This article reviewed the most recent mechanical tests conducted on porous hip implants constructed using additive manufacturing (AM), highlighting the boundary conditions, loading conditions, advantages, and disadvantages of the testing and AM methods. In conclusion, the use of lattice structure as well as the implementation of additive manufacturing processes for porous hip implant development are promising methods in terms of mechanical properties (31–62% better than conventional). Nevertheless, further in-vivo study should be conducted to check the reliability of porous implant when treating femoral bone.

Förderung

  • University of Technology Malaysia
  • Universitas Sriwijaya

Zitieren

APA

Abdullah, N. N. A. A., Ammarullah, M. I., Salaha, Z. F. M., Baharuddin, M. H., Kadir, M. R. A., & Ramlee, M. H. (2025). Bioinspired porous hip implants design: A systematic review of mechanical testing and additive manufacturing. Results in Engineering, 25, 103708. https://doi.org/10.1016/j.rineng.2024.103708

Vancouver

Abdullah NNAA, Ammarullah MI, Salaha ZFM, Baharuddin MH, Kadir MRA, Ramlee MH. Bioinspired porous hip implants design: A systematic review of mechanical testing and additive manufacturing. Results in Engineering. 2025;25:103708. doi:10.1016/j.rineng.2024.103708

BibTeX
@article{Abdullah2025,
  author = {Abdullah, Nik Nur Ain Azrin and Ammarullah, Muhammad Imam and Salaha, Zatul Faqihah Mohd and Baharuddin, Muhammad Hanif and Kadir, Mohammed Rafiq Abdul and Ramlee, Muhammad Hanif},
  title = {Bioinspired porous hip implants design: A systematic review of mechanical testing and additive manufacturing},
  journal = {Results in Engineering},
  year = {2025},
  volume = {25},
  pages = {103708},
  doi = {10.1016/j.rineng.2024.103708}
}
Kostenlos starten →