EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Numerical simulation of unsteady generic Newtonian blood flow and heat transfer through discrepant shaped dilatable arterial stenosis

Azad Hussain, Muhammad Naveel Riaz Dar, Warda Khalid Cheema, Elsayed M. Tag-eldin, Rimsha Kanwal

Results in Engineering · 2023-06 · 18 · 101189

DOI: 10.1016/j.rineng.2023.101189 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Results in Engineering, 2023-06. Verfasst von Azad Hussain und 4 weiteren Autor:innen. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The contemporaneous research was conducted to evaluate the attribute of blood flow and degree of obstruction generated in the arteries pathway through different geometries. Flow of blood via the stenosed afflicted arteries is taken into account in this work. The viscous, unsteady, incompressible and laminar, blood plunge into the artery with a speed of 0.049 m s−1. Partial differential equations were demonstrated for the current problem. Time dependent direct solver was used to obtain the solution. Finite element discretization method (FDM) is used to obtain the solution. The research was accomplished by using advanced computational fluid dynamics (CFD) software. The blood flow behavior was investigated in order to determine velocity, pressure, and temperature changes caused by an arterial stenosis. It was discovered that the shape of the stenosis has a crucial impact on the velocity, total pressure reduction and temperature over the arterial constriction zone. Graphs are plotted to illustrate the solutions. Results shows that the trapezoidal and elliptical stenosis had the greatest pressure decrease, followed by the triangular stenosis. These findings will be extremely beneficial in the treatment of stenotic arteries.

Zitieren

APA

Hussain, A., Dar, M. N. R., Cheema, W. K., Tag-eldin, E. M., & Kanwal, R. (2023). Numerical simulation of unsteady generic Newtonian blood flow and heat transfer through discrepant shaped dilatable arterial stenosis. Results in Engineering, 18, 101189. https://doi.org/10.1016/j.rineng.2023.101189

Vancouver

Hussain A, Dar MNR, Cheema WK, Tag-eldin EM, Kanwal R. Numerical simulation of unsteady generic Newtonian blood flow and heat transfer through discrepant shaped dilatable arterial stenosis. Results in Engineering. 2023;18:101189. doi:10.1016/j.rineng.2023.101189

BibTeX
@article{Hussain2023,
  author = {Hussain, Azad and Dar, Muhammad Naveel Riaz and Cheema, Warda Khalid and Tag-eldin, Elsayed M. and Kanwal, Rimsha},
  title = {Numerical simulation of unsteady generic Newtonian blood flow and heat transfer through discrepant shaped dilatable arterial stenosis},
  journal = {Results in Engineering},
  year = {2023},
  volume = {18},
  pages = {101189},
  doi = {10.1016/j.rineng.2023.101189}
}