Comparative assessment of cough capacity in patients with neuromuscular disease: Spirometer versus portable peak flow meter
Rehabilitación · 2025
DOI: 10.1016/j.rh.2025.100955 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Rehabilitación, 2025. Verfasst von A Balañá Corberó und 1 weiteren Autor:innen. Beteiligte Einrichtung: Servei de Pneumologia, Hospital del Mar, Barcelona, Cataluña, Spain; Unidad de Esclerosis Lateral Amiotrófica, Hospital del Mar, Barcelona, Cataluña,…. Hauptthemen laut MEDLINE: Cough, Spirometry, Neuromuscular Diseases. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Cough impairment in neuromuscular diseases (NMD) increases pulmonary infection risk. Peak cough flow (PCF) is crucial for assessment, with spirometry (PCFs) as gold standard. Portable peak flow meters (PCFp) are practical, yet their comparability with spirometers in NMD remains debated. This study compared PCFs and PCFp in NMD patients with restrictive lung disease. METHODS: A prospective, cross-sectional observational study included patients with NMD from a home mechanical ventilation unit. Inclusion criteria comprised a definitive diagnosis of NMD and the ability to perform forced expiratory maneuvers. PCF was measured using a calibrated spirometer (PCFs) and a portable peak flow meter (PCFp) in randomized order. The measurement protocol followed ATS/ERS 2019 standards. Agreement was evaluated using the Bland-Altman method and the Intraclass Correlation Coefficient (ICC). Data normality was assessed by the Shapiro-Wilk test. A p-value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Servei de Pneumologia, Hospital del Mar, Barcelona, Cataluña, Spain; Unidad de Esclerosis Lateral Amiotrófica, Hospital del Mar, Barcelona, Cataluña, Spain.
- Servei de Pneumologia, Hospital del Mar, Barcelona, Cataluña, Spain; Unidad de Esclerosis Lateral Amiotrófica, Hospital del Mar, Barcelona, Cataluña, Spain; CEXS, Universitat Pompeu Fabra, Barcelona, Cataluña, Spain; CI…
Zitieren
APA
Balañá Corberó, A., & Martínez Llorens, J. (2025). Comparative assessment of cough capacity in patients with neuromuscular disease: Spirometer versus portable peak flow meter. Rehabilitación. https://doi.org/10.1016/j.rh.2025.100955
Vancouver
Balañá Corberó A, Martínez Llorens J. Comparative assessment of cough capacity in patients with neuromuscular disease: Spirometer versus portable peak flow meter. Rehabilitación. 2025. doi:10.1016/j.rh.2025.100955
BibTeX
@article{BalaCorber2025,
author = {Balañá Corberó, A and Martínez Llorens, J},
title = {Comparative assessment of cough capacity in patients with neuromuscular disease: Spirometer versus portable peak flow meter},
journal = {Rehabilitación},
year = {2025},
doi = {10.1016/j.rh.2025.100955}
}
EUVIMED