End-tidal CO2 changes during short breath-hold maneuvers: Variability, paradigm effects, and spirometric correlates
Respiratory Physiology & Neurobiology · 2026
DOI: 10.1016/j.resp.2026.104637 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respiratory Physiology & Neurobiology, 2026. Verfasst von Leonie Zerweck und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, Tuebingen 72076, Germany; Departmen…. Hauptthemen laut MEDLINE: Carbon Dioxide, Breath Holding. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Breath-hold functional MRI (bh-fMRI) is a widely used method for mapping cerebrovascular reactivity (CVR). Normalization of BOLD signal changes to end-tidal CO₂ changes (ΔpetCO₂) is suggested to improve between-subject comparability. The aim was to characterize magnitude and variability of ΔpetCO₂ during short breath-hold maneuvers. Twenty healthy volunteers participated in this study. Ten of these participants performed five breathing paradigms: baseline breathing, and end-expiratory breath-holds of 6, 9, and 12 s, as well as a deep breathing maneuver, each repeated seven times. petCO₂ was recorded continuously via nasal cannula. Within- and between-subject variability were quantified using the coefficient of variation (CV). Differences in ΔpetCO₂ between paradigms were assessed using repeated-measures ANOVA. Ten additional participants underwent the 9 s breath-hold paradigm and spirometry; associations between ΔpetCO₂ and pulmonary volumes, age, and baseline petCO₂ were assessed using Pearson correlation. Within-subject within-paradigm CVs were low (3.4-4.7%), indicating high reproducibility. Between-subject CVs were substantially higher (19.7-35.3%). ΔpetCO₂ differed significantly between the 6 and 9 s paradigms (p = 0.014, pFDR = 0.017) but not between the 9 and 12 s paradigms (p = 0.209, pFDR = 0.209). The deep breathing induced a reproducible petCO₂ decrease. A very strong inverse correlation was observed between ΔpetCO₂ and inspiratory vital capacity (IVC) (r = -0.797 (95%CI: -0.950--0.336), p = 0.006, pFDR = 0.030). Short breath-hold maneuvers induce reproducible, yet variable CO₂ responses within individuals. Pulmonary anatomy is a key determinant of ΔpetCO₂. Inadvertent deep breathing prior to breath-holding may induce petCO₂ decreases of non-negligible magnitude, with potential implications for bh-fMRI interpretation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, Tuebingen 72076, Germany; Department of Neurosurgery, University Hospital Zurich, Rämistrasse 10, Zurich…
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, Tuebingen 72076, Germany. Electronic address: grete.schrade@student.uni-tuebingen.de.
- Anesthesiologic and Intensive Care Medicine, University Hospital TuebingenHoppe-Seyler-Straße 3, Tuebingen 72076, Germany. Electronic address: andreas.manger@med.uni-tuebingen.de.
- Department of Neurosurgery, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, Tuebingen 72076, Germany. Electronic address: patrick.haas@med.uni-tuebingen.de.
- Department of Sports Medicine, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, Tuebingen 72076, Germany; Department of Trauma Surgery, BG Trauma Center Tuebingen, Schnarrenbergstrasse 95, Tuebingen 72076, Germany.…
- Department of Sports Medicine, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, Tuebingen 72076, Germany. Electronic address: andreas.niess@med.uni-tuebingen.de.
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Zerweck, L., Schrade, G., Manger, A., Haas, P., Döbele, S., Nieß, A., Ernemann, U., & Hauser, T. K. (2026). End-tidal CO2 changes during short breath-hold maneuvers: Variability, paradigm effects, and spirometric correlates. Respiratory Physiology & Neurobiology. https://doi.org/10.1016/j.resp.2026.104637
Vancouver
Zerweck L, Schrade G, Manger A, Haas P, Döbele S, Nieß A, et al. End-tidal CO2 changes during short breath-hold maneuvers: Variability, paradigm effects, and spirometric correlates. Respiratory Physiology & Neurobiology. 2026. doi:10.1016/j.resp.2026.104637
BibTeX
@article{Zerweck2026,
author = {Zerweck, Leonie and Schrade, Grete and Manger, Andreas and Haas, Patrick and Döbele, Stefan and Nieß, Andreas and Ernemann, Ulrike and Hauser, Till-Karsten},
title = {End-tidal CO2 changes during short breath-hold maneuvers: Variability, paradigm effects, and spirometric correlates},
journal = {Respiratory Physiology & Neurobiology},
year = {2026},
doi = {10.1016/j.resp.2026.104637}
}
EUVIMED