Aortic coartation stenting in young population: height matters

Andrea Amici, Ga-Lem Bethge-Ng, Peter Ewert, Katarzyna Gendera, Stanimir Georgiev, Andreas Eicken, Maria von Stumm, Felix Berger, Pinar Bambul-Heck

Revista Española de Cardiología (English Edition) · 2026

DOI: 10.1016/j.rec.2025.12.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Española de Cardiología (English Edition), 2026. Verfasst von Andrea Amici und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology and Congenital Heart Defects, TUM University Hospital, German Heart Center Munich, Munich, Germany. Electronic add…. Hauptthemen laut MEDLINE: Aortic Coarctation, Stents, Body Height. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION AND OBJECTIVES: Stent implantation is an established treatment for aortic coarctation (CoA) in adults. In pediatric patients, however, ongoing somatic growth necessitates repeated stent redilations, and the optimal timing of these procedures remains undefined. This retrospective study aimed to identify an objective association between stent diameter and body growth parameters, thereby providing a basis for prognostic assessment and structured planning of redilation strategies. METHODS: In the derivation cohort, all stent implantations and redilations performed in 155 patients younger than 20 years with CoA at a tertiary center were analyzed (218 interventions; median age 10.1 years, IQR, 3.4-14.4). The findings were subsequently validated in an independent validation cohort from another tertiary center, comprising 198 patients (323 interventions; median age 7.5 years, IQR, 1.3-14.6). RESULTS: To assess the association between stent diameter and body growth parameters, correlation analyses were performed. Despite interindividual variability, a significant linear correlation between stent diameter and body height was identified (τ: 0.737, P≤.001) and this finding was confirmed in the validation cohort. Based on this relationship, a formula, f(x)=0.0831·x+1.86, where x represents body height, was derived to estimate the appropriate stent diameter. This formula yields minimum and maximum reference body heights for each stent diameter, which are reached at different ages depending on individual growth velocity. These results were subsequently translated into sex-specific reference tables. CONCLUSIONS: The derived formula enables prediction of the required stent diameter and the anticipated number of subsequent catheter-based procedures, thereby supporting rapid estimation of intervention timing throughout somatic growth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic CoarctationStentsBody HeightHumansRetrospective StudiesMaleFemaleChildChild, PreschoolAdolescentInfantProsthesis DesignFollow-Up StudiesTreatment Outcome

Stichwörter der Autor:innen

AngioplastiaAngioplastyAortaAortic coarctationBalloonBalónBebés/niños/adolescentesCoartación aórticaEndovascular proceduresInfant/child/adolescentProcedimientos endovascularesStentsThoracicTorácica

Autor:innen und Institutionen

  • Department of Pediatric Cardiology and Congenital Heart Defects, TUM University Hospital, German Heart Center Munich, Munich, Germany. Electronic address: amici@dhm.mhn.de.
  • Department of Internal Medicine and Cardiology, Oberhavel Kliniken, Klinikum Henningsdorf, Henningsdorf, Germany.
  • Department of Pediatric Cardiology and Congenital Heart Defects, TUM University Hospital, German Heart Center Munich, Munich, Germany.
  • Department for Congenital and Pediatric Heart Surgery, TUM University Hospital, German Heart Center Munich, Munich, Germany; Division for Congenital and Pediatric Heart Surgery, University Hospital Großhadern, Ludwig-Ma…
  • Department of Pediatric Cardiology and Congenital Heart Defects, German Heart Centre of the Charité, Berlin, Germany.

Zitieren

APA

Amici, A., Bethge-Ng, G. L., Ewert, P., Gendera, K., Georgiev, S., Eicken, A., von Stumm, M., Berger, F., & Bambul-Heck, P. (2026). Aortic coartation stenting in young population: height matters. Revista Española de Cardiología (English Edition). https://doi.org/10.1016/j.rec.2025.12.018

Vancouver

Amici A, Bethge-Ng GL, Ewert P, Gendera K, Georgiev S, Eicken A, et al. Aortic coartation stenting in young population: height matters. Revista Española de Cardiología (English Edition). 2026. doi:10.1016/j.rec.2025.12.018

BibTeX
@article{Amici2026,
  author = {Amici, Andrea and Bethge-Ng, Ga-Lem and Ewert, Peter and Gendera, Katarzyna and Georgiev, Stanimir and Eicken, Andreas and von Stumm, Maria and Berger, Felix and Bambul-Heck, Pinar},
  title = {Aortic coartation stenting in young population: height matters},
  journal = {Revista Española de Cardiología (English Edition)},
  year = {2026},
  doi = {10.1016/j.rec.2025.12.018}
}
Kostenlos starten →