Results of open reduction and cortico-cancellous autograft of intra-articular calcaneal fractures according to Palmer
Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur · 2008
DOI: 10.1016/j.rco.2007.04.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur, 2008. Verfasst von M Di Schino und 4 weiteren Autor:innen. Beteiligte Einrichtung: Service de Chirurgie Orthopédique et Traumatologique, Hôpital Européen Georges-Pompidou, Paris cedex 15, France. Hauptthemen laut MEDLINE: Bone Transplantation. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To assess the mid term patient outcome after operative treatment of a displaced intra-articular calcaneal fracture using the modified Palmer technique. MATERIALS AND METHODS: Eighteen operatively treated intra-articular fractures of the calcaneus in 16 patients (nine males, seven females) were retrospectively reviewed. The mean age at surgery was 35 years (range, 17-61 years). Two patients had a bilateral fracture. Following Utheza, five fractures (28%) were classified as vertical, three as horizontal (17%) and 10 (55%) as combined. Mean preoperative Böhler angle was -4 degrees (range, -42 to 26 degrees ). An extended lateral approach to the calcaneus was used in each case. A cortical bone autograft was firmly impacted in the subthalamic void after reduction. Stabilization was achieved by two or three axial Kirschner wires and one or two screws inserted in a transverse position. Patients were evaluated at the last follow-up by physical examination and by the functional score described by Kitaoka. Böhler's angle was measured on the immediate postoperative radiographs and at the last follow-up, and compared when possible with the noninjured side. RESULTS: Follow-up ranged from 12 to 38 months (mean, 23 months). One patient required a subtalar arthrodesis for advanced osteoarthritis. One patient experienced reflex sympathetic dystrophy. No skin complication was noted. At the last follow-up evaluation, the mean Kitaoka score was 74 (range, 34-98). The functional score was considered good or excellent in 11 cases (64.7%), fair in three (17.6%), and poor in three (17.6%). The mean Böhler angle was 23.4 degrees (range, 5-40 degrees ) postoperatively and 22.7 degrees (range, 0-38 degrees ) at the last follow-up. A modest loss of correction was observed in four cases. The final Böhler angle was at least 85% compared to the healthy side in 10 cases out of 14 unilateral fractures. The functional score correlated well with restoration of Böhler's angle. DISCUSSION AND CONCLUSION: Operative treatment of intra-articular calcaneal fractures following a modified Palmer technique provided encouraging results, since restoration of Böhler's angle was obtained. The main advantages include an absence of hardware prominence, resulting in an absence of skin complications, and a stable fixation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Européen Georges-Pompidou, Paris cedex 15, France.
Zitieren
APA
Di Schino, M., Bensaïda, M., Vandenbussche, E., Augereau, B., & Nich, C. (2008). Results of open reduction and cortico-cancellous autograft of intra-articular calcaneal fractures according to Palmer. Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur. https://doi.org/10.1016/j.rco.2007.04.007
Vancouver
Di Schino M, Bensaïda M, Vandenbussche E, Augereau B, Nich C. Results of open reduction and cortico-cancellous autograft of intra-articular calcaneal fractures according to Palmer. Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur. 2008. doi:10.1016/j.rco.2007.04.007
BibTeX
@article{DiSchino2008,
author = {Di Schino, M and Bensaïda, M and Vandenbussche, E and Augereau, B and Nich, C},
title = {Results of open reduction and cortico-cancellous autograft of intra-articular calcaneal fractures according to Palmer},
journal = {Revue de Chirurgie Orthopédique et Réparatrice de l'Appareil Moteur},
year = {2008},
doi = {10.1016/j.rco.2007.04.007}
}
EUVIMED