EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fracture detection using a low-dose computed tomography paediatric bone fracture phantom: A multi-reader study of radiographers

E Doyle, J F Dipnall, M R Dimmock, K L Lee, M E Suleiman, O J Arthurs, J McInerney, A C Offiah, R R van Rijn, R B Bassed

Radiography · 2026

DOI: 10.1016/j.radi.2026.103333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiography, 2026. Verfasst von E Doyle und 9 weiteren Autor:innen. Beteiligte Einrichtung: Monash University, Department of Forensic Medicine, Melbourne, VIC, Australia. Electronic address: edel.doyle@monash.edu. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Fractures, Bone, Child Abuse, Phantoms, Imaging. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Society of Medical Imaging and Radiation Therapy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Low-dose computed tomography (CT) has been proposed as an alternative approach to investigate suspected physical abuse (SPA). This is an important consideration for children under 1 year of age due to the inconvenience of initial and follow-up imaging in addition to CT of the head. Results from a pilot study using a bone fracture paediatric phantom suggested that fracture detection was inconsistent using low-dose CT. The aim of this study was to evaluate whether those findings were consistent for a larger cohort of observers. METHODS: Nine CT datasets were reviewed by 18 radiographers who marked the fractures using specialist image viewing software. Fractures detected were compared to the known fractures in the commercial paediatric bone fracture phantom. Sensitivity, specificity, positive and negative predictive values (PPV, NPV), with bootstrapped 95 % confidence interval (CI), were calculated. RESULTS: None of the observers detected all seven fractures, with a maximum of five identified by four observers. Bootstrapping predicted that the most commonly detected fractures were of the skull with a sensitivity of 88 %, specificity of 67 %, 95 % CI for PPV ranging from 96 to 99 % and NPV of 15-44 % and the tibia and fibula with a sensitivity of 70 %, specificity of 83 %, 95 % CI for PPV ranging from 93 to 99 % and NPV of 16-45 %. CONCLUSION: Radiographers had overall sensitivity of 60 % for fracture detection on this phantom, unaffected by radiation dose, but with large variability between observers. Therefore, more research is required to identify the factors that may have influenced this, such as experience, fracture or phantom-based effect. IMPLICATIONS FOR PRACTICE: There is currently no evidence to support a change in current clinical practice which is the radiographic skeletal survey series to investigate SPA in children.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedFractures, BoneChild AbusePhantoms, ImagingHumansRadiation DosageSensitivity and SpecificityInfantObserver VariationForensic Imaging

Stichwörter der Autor:innen

Computed tomographyFractureNon-accidental injuryPaediatricPhysical abuse

Autor:innen und Institutionen

  • Monash University, Department of Forensic Medicine, Melbourne, VIC, Australia. Electronic address: edel.doyle@monash.edu.
  • School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia; School of Medicine, Deakin University, Geelong, VIC, Australia. Electronic address: joanna.dipnall@monash.edu.
  • Monash University, Department of Medical Imaging and Radiation Sciences, Melbourne, VIC, Australia. Electronic address: matthew.dimmock@monash.edu.
  • Australian Radiation Protection and Nuclear Safety Agency, Yallambie, VIC, Australia. Electronic address: kam.lee@arpansa.gov.au.
  • DetectedX, Sydney, NSW, Australia. Electronic address: moe.suleiman@detectedx.com.
  • Radiology Department, Great Ormond Street Hospital, London, UK; UCL GOS Institute of Child Health, London, UK; NIHR Great Ormond Street Biomedical Research Centre, London, UK. Electronic address: Owen.Arthurs@gosh.nhs.u…

Förderung

  • Australian Society of Medical Imaging and Radiation Therapy

Zitieren

APA

Doyle, E., Dipnall, J. F., Dimmock, M. R., Lee, K. L., Suleiman, M. E., Arthurs, O. J., McInerney, J., Offiah, A. C., van Rijn, R. R., & Bassed, R. B. (2026). Fracture detection using a low-dose computed tomography paediatric bone fracture phantom: A multi-reader study of radiographers. Radiography. https://doi.org/10.1016/j.radi.2026.103333

Vancouver

Doyle E, Dipnall JF, Dimmock MR, Lee KL, Suleiman ME, Arthurs OJ, et al. Fracture detection using a low-dose computed tomography paediatric bone fracture phantom: A multi-reader study of radiographers. Radiography. 2026. doi:10.1016/j.radi.2026.103333

BibTeX
@article{Doyle2026,
  author = {Doyle, E and Dipnall, J F and Dimmock, M R and Lee, K L and Suleiman, M E and Arthurs, O J and McInerney, J and Offiah, A C and van Rijn, R R and Bassed, R B},
  title = {Fracture detection using a low-dose computed tomography paediatric bone fracture phantom: A multi-reader study of radiographers},
  journal = {Radiography},
  year = {2026},
  doi = {10.1016/j.radi.2026.103333}
}
Kostenlos starten →