EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Can radiographer regulatory compliance contribute to patient safety in the emergency department fast-track pathway? A retrospective pilot study

B Pearce, S Uribe, C Cowling, J-A Pinson, W Smith, J Sim

Radiography · 2025

DOI: 10.1016/j.radi.2024.10.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiography, 2025. Verfasst von B Pearce und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Peninsula Health, Melbourne, Victoria, Australia; Dept. of Medical Imaging and Radiation Sciences, Faculty of Medicine…. Hauptthemen laut MEDLINE: Emergency Service, Hospital, Patient Safety, Guideline Adherence, Radiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Radiographers in clinical imaging pathways ensure regulatory compliance by justifying X-ray requests, optimising exposure, and communicating urgent findings. In Australia, adherence to Australian regulatory directives is crucial for patient safety, particularly in Emergency Departments (EDs) where immediate radiologist report or guidance may be unavailable. This study explores whether Australian radiographers working within regulatory compliance of justification, optimisation and Preliminary Image Evaluation (PIE) in the ED contribute to improving patient safety? METHODS: In a retrospective blinded single-phase study, 28 radiographers reviewed 50 cases of single extremity trauma in the ED Fast-Track (FT) pathway. Data analysis assessed compliance with regulatory directives, evaluating justification, optimisation, and accuracy of Preliminary Image Evaluations (PIE) against established standards. RESULTS: Justification: Radiographers found 67.8 % (n = 881) of X-ray requests compliant and 32.2 % (n = 419) non-compliant. Optimisation: Participants optimised referrals by correcting anatomical selection (52.0 %, n = 676), adjusting the number of images (11.6 %, n = 151), or both (17.5 %, n = 227). PIE: Radiographer PIE demonstrated a mean sensitivity of 94.7 % (CI: 92.9 %-96.6 %), specificity of 89.6 % (CI: 87.0 %-92.2 %), and accuracy of 92.7 % (CI: 91.6 %-93.8 %). The average Positive Predictive Value (PPV) was 93.2 % (CI: 92.0-94.9 %), the Negative Predictive Value (NPV) was 91.9 % (CI: 90.2-95.0 %), and Cohen's Kappa inter-rater reliability median was K = 0.85, with an average result of K = 0.85 (range: K = 0.74 to K = 0.96). CONCLUSION: In this study, radiographer compliance with regulatory standards for justification, optimisation, and PIE is high but not fully consistent. When radiographers adhere to regulations, there is potential to improve patient safety. Collaborative compliance between radiologists, referrers, and radiographers within the ED FT pathway could further improve patient safety outcomes. Additional research, including prospective studies, is necessary to further evaluate radiographer compliance in the ED FT pathway. IMPLICATIONS FOR PRACTICE: Radiographers are professionally obligated to follow Australian regulatory directives for safe medical radiation practice, guided by imaging protocols. Timely and accurate PIE by radiographers can enhance patient safety in ED.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Emergency Service, HospitalPatient SafetyGuideline AdherenceRadiographyCritical PathwaysHumansRetrospective StudiesPilot ProjectsAustraliaFemaleMaleAdult

Stichwörter der Autor:innen

JustificationOptimisationPatient safetyPreliminary image evaluationRegulatory compliance

Autor:innen und Institutionen

  • Department of Medical Imaging, Peninsula Health, Melbourne, Victoria, Australia; Dept. of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia.…
  • Dept. of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia. Electronic address: sergio.uribe@monash.edu.
  • Dept. of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia. Electronic address: cynthia.cowling@monash.edu.
  • Medicinal Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, Parkville, Australia. Electronic address: jo-anne.pinson@petermac.org.
  • Department of Medical Imaging, Peninsula Health, Melbourne, Victoria, Australia. Electronic address: wadesmith@phcn.vic.gov.au.
  • Dept. of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia. Electronic address: jenny.sim@monash.edu.

Zitieren

APA

Pearce, B., Uribe, S., Cowling, C., Pinson, J. A., Smith, W., & Sim, J. (2025). Can radiographer regulatory compliance contribute to patient safety in the emergency department fast-track pathway? A retrospective pilot study. Radiography. https://doi.org/10.1016/j.radi.2024.10.014

Vancouver

Pearce B, Uribe S, Cowling C, Pinson JA, Smith W, Sim J. Can radiographer regulatory compliance contribute to patient safety in the emergency department fast-track pathway? A retrospective pilot study. Radiography. 2025. doi:10.1016/j.radi.2024.10.014

BibTeX
@article{Pearce2025,
  author = {Pearce, B and Uribe, S and Cowling, C and Pinson, J-A and Smith, W and Sim, J},
  title = {Can radiographer regulatory compliance contribute to patient safety in the emergency department fast-track pathway? A retrospective pilot study},
  journal = {Radiography},
  year = {2025},
  doi = {10.1016/j.radi.2024.10.014}
}
Kostenlos starten →