EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Super-Selective Embolization Using Flow-Directed Microcatheter and 0.010-inch Microwire for Type II Endoleak Following Thoracic Endovascular Aortic Repair: A Three-Case Report

Hiroki Kamada, Sota Oguro, Hiromitsu Tannai, Hiroyuki Sakakibara, Kei Takase

Radiology Case Reports · 2026-01 · 21 (1) · 1-8

DOI: 10.1016/j.radcr.2025.09.040 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Radiology Case Reports, 2026-01. Verfasst von Hiroki Kamada und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tohoku University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Type II endoleak (T2EL) following thoracic endovascular aortic repair (TEVAR) may lead to progressive aneurysm enlargement, necessitating further intervention. This report presents 3 cases of persistent T2EL with aneurysm growth after TEVAR, and managed through endovascular embolization using flow-directed microcatheters and 0.010-inch guidewires, employing N-butyl cyanoacrylate (NBCA) either alone or in combination with coils. Aneurysmal sac embolization was successfully performed in all cases, despite significant vascular tortuosity, resulting in favorable immediate outcomes without complications. A key advantage observed was the ability of flow-directed microcatheters to navigate into distal, tortuous feeding vessels that are typically inaccessible using conventional methods. While NBCA alone was effective for embolizing small sacs, a combination of coils and NBCA provided more controlled and stable embolization in larger sacs. However, follow-up computed tomography revealed new endoleaks in 2 cases, emphasizing the need for continued monitoring. While short-term results are promising, further studies are needed to assess long-term recurrence risks. This case series highlights the effectiveness of flow-directed microcatheters, 0.010-inch microwires, and targeted embolization techniques in managing T2EL following TEVAR.

Schlagwörter

Stichwörter der Autor:innen

Endovascular embolizationFlow-directed microcathetersN-butyl cyanoacrylateThoracic endovascular aortic repairType II endoleak

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan.

Förderung

  • Tohoku University

Zitieren

APA

Kamada, H., Oguro, S., Tannai, H., Sakakibara, H., & Takase, K. (2026). Super-Selective Embolization Using Flow-Directed Microcatheter and 0.010-inch Microwire for Type II Endoleak Following Thoracic Endovascular Aortic Repair: A Three-Case Report. Radiology Case Reports, 21(1), 1-8. https://doi.org/10.1016/j.radcr.2025.09.040

Vancouver

Kamada H, Oguro S, Tannai H, Sakakibara H, Takase K. Super-Selective Embolization Using Flow-Directed Microcatheter and 0.010-inch Microwire for Type II Endoleak Following Thoracic Endovascular Aortic Repair: A Three-Case Report. Radiology Case Reports. 2026;21(1):1-8. doi:10.1016/j.radcr.2025.09.040

BibTeX
@article{Kamada2026,
  author = {Kamada, Hiroki and Oguro, Sota and Tannai, Hiromitsu and Sakakibara, Hiroyuki and Takase, Kei},
  title = {Super-Selective Embolization Using Flow-Directed Microcatheter and 0.010-inch Microwire for Type II Endoleak Following Thoracic Endovascular Aortic Repair: A Three-Case Report},
  journal = {Radiology Case Reports},
  year = {2026},
  volume = {21},
  number = {1},
  pages = {1--8},
  doi = {10.1016/j.radcr.2025.09.040}
}
Kostenlos starten →