EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reliability and validity of upper extremity neurocognitive reactive tests in collegiate athletes

Matthew L Gauthier, Marisa Pontillo, George James Davies

Physical Therapy in Sport · 2026-11 · 82 · 101992

DOI: 10.1016/j.ptsp.2026.101992 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Therapy in Sport, 2026-11. Verfasst von Matthew L Gauthier und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, College of Applied Health Sciences, University of Illinois at Chicago, Chicago, IL, 60608, USA. Electronic address: m…. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Neurocognitive function is vital in sports, but evidence supporting neurocognitive reaction testing in upper extremity return-to-sport testing is limited. This study's purpose was to quantify measurement properties of upper extremity reactive testing in collegiate athletes, hypothesizing acceptable measurement properties for clinical use. DESIGN: Cross-Sectional Study. SETTING: Collegiate athletics. PARTICIPANTS: Sixty-three healthy athletes (25 females, age = 20.8 ± 1.6 years, BMI = 25.6 ± 2.6 kg/m2; 38 males, age = 20.8 ± 1.6, BMI = 25.7 ± 2.6 kg/m2). MAIN OUTCOME MEASURE(S): Successful touches and average reaction time on the Upper Extremity Reactive Closed Kinetic Chain Test (UERCKCT) and Upper Extremity Reactive Open Kinetic Chain Test (UEROKCT); successful touches on the Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST). RESULTS: Reliability of UERCKCT and UEROKCT was good-to-excellent (ICC3,1 = 0.75-0.94), except for one condition. UERCKCT and UEROKCT touches demonstrated moderate-to-large correlation with CKCUEST (r = 0.40-0.67, p 0.05). CONCLUSIONS: The UERCKCT and UEROKCT demonstrated good-to-excellent reliability and demonstrated convergent validity with an established proactive test. UEROKCT demonstrates symmetrical limb performance. This is the first study to show acceptable reliability and preliminary convergent validity of these tests for clinical assessment of neurocognitive function.

Schlagwörter

Stichwörter der Autor:innen

Athletic performanceNeurocognitive reactive testingReturn to sportUpper extremity

Autor:innen und Institutionen

  • Department of Physical Therapy, College of Applied Health Sciences, University of Illinois at Chicago, Chicago, IL, 60608, USA. Electronic address: mgauthie@uic.edu.
  • Extremity Trauma and Amputation Center of Excellence, Defense Health Agency, Falls Church, VA, 22042, USA; Department of Physical and Occupational Therapy, Chiropractic Services, and Sports Medicine, Naval Medical Cente…
  • Department of Physical Therapy, University of Texas-Rio Grande Valley, Edinburg, TX., 78539, USA. Electronic address: gjd.sportspt@gmail.com.

Zitieren

APA

Gauthier, M. L., Pontillo, M., & Davies, G. J. (2026). Reliability and validity of upper extremity neurocognitive reactive tests in collegiate athletes. Physical Therapy in Sport, 82, 101992. https://doi.org/10.1016/j.ptsp.2026.101992

Vancouver

Gauthier ML, Pontillo M, Davies GJ. Reliability and validity of upper extremity neurocognitive reactive tests in collegiate athletes. Physical Therapy in Sport. 2026;82:101992. doi:10.1016/j.ptsp.2026.101992

BibTeX
@article{Gauthier2026,
  author = {Gauthier, Matthew L and Pontillo, Marisa and Davies, George James},
  title = {Reliability and validity of upper extremity neurocognitive reactive tests in collegiate athletes},
  journal = {Physical Therapy in Sport},
  year = {2026},
  volume = {82},
  pages = {101992},
  doi = {10.1016/j.ptsp.2026.101992}
}
Kostenlos starten →