EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Reliability and validity of belt-stabilized and tension dynamometry for assessing hip strength and power in uninjured adults

Natanael P Batista, Zuleiha I Rachid, Danilo De Oliveira Silva, Neal R Glaviano, Grant E Norte, David M Bazett-Jones

Physical Therapy in Sport · 2024

DOI: 10.1016/j.ptsp.2024.07.004 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Physical Therapy in Sport, 2024. Verfasst von Natanael P Batista und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Exercise and Rehabilitation Sciences, Health & Human Services, University of Toledo, Mail Stop 1199, 201 W. Bancroft St, Toledo, OH, 43606-…. Hauptthemen laut MEDLINE: Muscle Strength Dynamometer, Muscle Strength, Torque. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To investigate the intra-rater reliability and validity of belt-stabilized and tension dynamometry to assess hip muscle strength and power. DESIGN: Repeated measures. SETTING: Biomechanics laboratory. PARTICIPANTS: Seventeen uninjured adults (age = 22.0 ± 2.3y; 13 females). MAIN OUTCOMES MEASURES: Peak torque (strength) and rate of torque development (RTD; power) were measured for hip abduction, internal rotation, external rotation and extension using an isokinetic dynamometer, and belt-stabilized and tension dynamometry. RESULTS: For peak torque assessment, belt-stabilized and tension dynamometry showed good (Intraclass Correlation Coefficient [ICC] = 0.848-0.899) and good-to-excellent (ICC = 0.848-0.942) reliability, respectively. For RTD, belt-stabilized dynamometry showed fair reliability for abduction (ICC = 0.524) and good reliability for hip internal rotation, external rotation, and extension (ICC = 0.702-0.899). Tension dynamometry showed good reliability for all motions when measuring RTD (ICC = 0.737-0.897). Compared to isokinetic dynamometry, belt-stabilized and tension dynamometry showed good-to-excellent correlations for peak torque assessment (r = 0.503-0.870), and fair-to-good correlations for RTD (r = 0.438-0.674). Bland-Altman analysis showed that measures from belt-stabilized and tension dynamometry had clinically meaningful disagreement with isokinetic dynamometry. CONCLUSION: Tension dynamometry is reliable for assessing hip strength and power in all assessed motions. Belt-stabilized dynamometry is reliable for assessing internal rotation, external rotation, and extension. Validity of both methods is questionable, considering the lack of agreement with isokinetic dynamometry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle Strength DynamometerMuscle StrengthTorqueHumansFemaleMaleReproducibility of ResultsYoung AdultAdultHipHip JointRange of Motion, ArticularMuscle, Skeletal

Stichwörter der Autor:innen

HipMuscle strengthReproducibility of resultsTorque

Autor:innen und Institutionen

  • School of Exercise and Rehabilitation Sciences, Health & Human Services, University of Toledo, Mail Stop 1199, 201 W. Bancroft St, Toledo, OH, 43606-3390, USA.
  • La Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, Victoria, Australia; Discipline of Physiotherapy, School of Allied Health, Human S…
  • Department of Kinesiology, University of Connecticut, Storrs, CT, USA.
  • Institute of Exercise Physiology and Rehabilitation Sciences, University of Central Florida, Orlando, FL, USA.
  • School of Exercise and Rehabilitation Sciences, Health & Human Services, University of Toledo, Mail Stop 1199, 201 W. Bancroft St, Toledo, OH, 43606-3390, USA. Electronic address: David.BazettJones@UToledo.edu.

Zitieren

APA

Batista, N. P., Rachid, Z. I., De Oliveira Silva, D., Glaviano, N. R., Norte, G. E., & Bazett-Jones, D. M. (2024). Reliability and validity of belt-stabilized and tension dynamometry for assessing hip strength and power in uninjured adults. Physical Therapy in Sport. https://doi.org/10.1016/j.ptsp.2024.07.004

Vancouver

Batista NP, Rachid ZI, De Oliveira Silva D, Glaviano NR, Norte GE, Bazett-Jones DM. Reliability and validity of belt-stabilized and tension dynamometry for assessing hip strength and power in uninjured adults. Physical Therapy in Sport. 2024. doi:10.1016/j.ptsp.2024.07.004

BibTeX
@article{Batista2024,
  author = {Batista, Natanael P and Rachid, Zuleiha I and De Oliveira Silva, Danilo and Glaviano, Neal R and Norte, Grant E and Bazett-Jones, David M},
  title = {Reliability and validity of belt-stabilized and tension dynamometry for assessing hip strength and power in uninjured adults},
  journal = {Physical Therapy in Sport},
  year = {2024},
  doi = {10.1016/j.ptsp.2024.07.004}
}
Kostenlos starten →