EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

It's time to regulate – The importance of accurate surgical-grade tourniquet autoregulation in blood flow restriction exercise applications

L Hughes, P M Swain, T Lai, J A McEwen

Physical Therapy in Sport · 2024

DOI: 10.1016/j.ptsp.2024.02.001 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Physical Therapy in Sport, 2024. Verfasst von L Hughes und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport, Exercise & Rehabilitation, Northumbria University, NE18ST, UK. Electronic address: luke4.hughes@northumbria.ac.uk. Hauptthemen laut MEDLINE: Tourniquets, Cross-Over Studies, Homeostasis. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Evaluate the efficacy of five common blood flow restriction (BFR) systems to accurately maintain and autoregulate BFR pressure in the tourniquet cuff near target pressure throughout exercise. DESIGN: Randomised crossover design. SETTING: Laboratory. PARTICIPANTS: 15 healthy individuals. OUTCOME MEASURES: 1) Percentage of total BFR time that surgical-grade tourniquet autoregulation, defined as automatic and rapid self-regulation of cuff pressure to within ±15 mmHg of initial target pressure within 1 s in the presence of transient pressure changes associated with exercise, was provided; 2) pressure change in the BFR cuff throughout exercise, by comparing the initial target pressure to the measured pressure at completion of BFR exercise. RESULTS: One BFR system could provide surgical-grade tourniquet autoregulation for the whole duration (100 ± 0%) of the BFR exercise in all subjects. In two of the five BFR systems evaluated, measured cuff pressure at the end of exercise was not different (p < 0.05) to the initial target pressure. CONCLUSIONS: Surgical-grade tourniquet autoregulation is important to consistently and reliably apply a targeted BFR pressure stimulus. This may allow BFR methodology and protocols to be accurately implemented and controlled so that the results can be more meaningfully compared, leading to the potential optimization of applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TourniquetsCross-Over StudiesHomeostasisHumansMaleFemaleAdultBlood Flow Restriction TherapyRegional Blood FlowYoung AdultExercise

Stichwörter der Autor:innen

AutoregulationBlood flow restrictionPressureTourniquet

Autor:innen und Institutionen

  • Department of Sport, Exercise & Rehabilitation, Northumbria University, NE18ST, UK. Electronic address: luke4.hughes@northumbria.ac.uk.
  • Department of Sport, Exercise & Rehabilitation, Northumbria University, NE18ST, UK.
  • Western Clinical Engineering Ltd., Vancouver British Columbia, Canada.
  • Western Clinical Engineering Ltd., Vancouver British Columbia, Canada; School of Biomedical Engineering and Departments of Orthopaedics and Electrical and Computer Engineering, University of British Columbia, Vancouver…

Zitieren

APA

Hughes, L., Swain, P. M., Lai, T., & McEwen, J. A. (2024). It's time to regulate – The importance of accurate surgical-grade tourniquet autoregulation in blood flow restriction exercise applications. Physical Therapy in Sport. https://doi.org/10.1016/j.ptsp.2024.02.001

Vancouver

Hughes L, Swain PM, Lai T, McEwen JA. It's time to regulate – The importance of accurate surgical-grade tourniquet autoregulation in blood flow restriction exercise applications. Physical Therapy in Sport. 2024. doi:10.1016/j.ptsp.2024.02.001

BibTeX
@article{Hughes2024,
  author = {Hughes, L and Swain, P M and Lai, T and McEwen, J A},
  title = {It's time to regulate – The importance of accurate surgical-grade tourniquet autoregulation in blood flow restriction exercise applications},
  journal = {Physical Therapy in Sport},
  year = {2024},
  doi = {10.1016/j.ptsp.2024.02.001}
}
Kostenlos starten →