Impact of Adherence to Target Volume Contouring Guidelines on Patterns-of-Failure in Sacral Stereotactic Body Radiation Therapy
Practical Radiation Oncology · 2026-07
DOI: 10.1016/j.prro.2026.07.001 ↗Kurz gefasst
Leitlinie in der Zeitschrift Practical Radiation Oncology, 2026-07. Verfasst von Daniel Moore-Palhares und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: We previously demonstrated that adherence to sacral stereotactic body radiation therapy (SBRT) clinical target volume (CTV) contouring guidelines is independently associated with reduced risk of local failure (LF). We hypothesized that this benefit results from coverage of involved and adjacent boney sectors at risk of subclinical disease and performed a pattern-of-failure analysis to evaluate the impact of including or excluding these guideline-recommended sectors in the CTV. METHODS AND MATERIALS: Of 209 sacral segments treated with SBRT between 2010 and 2021, 48 developed magnetic resonance imaging-based LF and were analyzed. Failures were mapped by boney sectors and classified as contoured per guidelines (adherent) or recommended but not included in the treated CTV (nonadherent). Dose-volume histogram metrics in nonadherent sectors with subsequent LF were compared with the treated CTV for that segment. RESULTS: Most metastases developing LF involved S1 (42%, 20/48) and S2 (31%, 15/48), were radioresistant (54%, 26/48), and had baseline extraosseous extension (71%, 34/48). Sixty-nine percent (33/48) of segments with LF were adherent, whereas 31% (15/48) were nonadherent. Among all 209 segments, those treated with a nonadherent CTV had higher rates of failure in the involved (37.1% vs 17.8%; P = .021) and guideline-recommended adjacent sectors (22.9% vs 2.3%; P < .001) than adherent CTV segments. Among adherent segments, most failures occurred exclusively within boney sectors included in the CTV (91%, 30/33). In contrast, 73% (11/15) of failures among nonadherent segments occurred in boney sectors that were recommended but incompletely contoured or omitted from the CTV. The mean equivalent dose in 2-Gy fractions (α/β = 10) was significantly lower at 38.7 Gy (IQR, 30.6-42.2) within those nonadherent sectors with tumor progression as compared with the dose in the corresponding treated CTV at 48.2 Gy (IQR, 46.6-49.4; P < .001). CONCLUSIONS: Anatomic and dosimetric sector-based pattern-of-failure analyses specific to sacral SBRT support CTV practice guidelines.
Autor:innen und Institutionen
- Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada.
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada.
- Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada. Electronic address: jay.detsky@sunnybrook.ca.
Zitieren
APA
Moore-Palhares, D., Zeng, K. L., Tseng, C. L., Chen, H., Soliman, H., Dinakaran, D., Maralani, P., Ruschin, M., Zhang, B., Sahgal, A., & Detsky, J. (2026). Impact of Adherence to Target Volume Contouring Guidelines on Patterns-of-Failure in Sacral Stereotactic Body Radiation Therapy. Practical Radiation Oncology. https://doi.org/10.1016/j.prro.2026.07.001
Vancouver
Moore-Palhares D, Zeng KL, Tseng CL, Chen H, Soliman H, Dinakaran D, et al. Impact of Adherence to Target Volume Contouring Guidelines on Patterns-of-Failure in Sacral Stereotactic Body Radiation Therapy. Practical Radiation Oncology. 2026. doi:10.1016/j.prro.2026.07.001
BibTeX
@article{MoorePalhares2026,
author = {Moore-Palhares, Daniel and Zeng, Kang Liang and Tseng, Chia-Lin and Chen, Hanbo and Soliman, Hany and Dinakaran, Deepak and Maralani, Pejman and Ruschin, Mark and Zhang, Beibei and Sahgal, Arjun and Detsky, Jay},
title = {Impact of Adherence to Target Volume Contouring Guidelines on Patterns-of-Failure in Sacral Stereotactic Body Radiation Therapy},
journal = {Practical Radiation Oncology},
year = {2026},
doi = {10.1016/j.prro.2026.07.001}
}
EUVIMED