A Case-Based Guide: Demonstrating the Reirradiation Collaborative Group (ReCOG) Consensus for Dosimetric Assessment and Reporting in Reirradiation
Practical Radiation Oncology · 2026-11 · 16 (6) · e553-e563
DOI: 10.1016/j.prro.2026.03.010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Practical Radiation Oncology, 2026-11. Verfasst von Claire Zhang und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The University of Michigan, Ann Arbor, Michigan. Electronic address: zhclaire@med.umich.edu. Hauptthemen laut MEDLINE: Re-Irradiation, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Siemens.
Abstract (Originalsprache)
PURPOSE: To provide case-based, practical examples outlining step-by-step calculations and documentation for reirradiation (reRT) evaluation. The representative examples demonstrate the application of the Reirradiation Collaborative Group (ReCOG) consensus for dosimetric assessment and reporting in reRT and illustrate how these standards can be implemented in clinical practice. METHODS AND MATERIALS: Two spine reRT cases were selected. Cumulative organ-at-risk doses were assessed using 3 approaches: direct point dose summation, point dose summation within overlap regions, and image registration-based 3-dimensional dose summation. Step-by-step calculations were performed for each approach, and new dose objectives for subsequent planning iterations were derived and compared. RESULTS: The example reRT cases detail the special medical physics consult process, highlighting different cumulative dose estimation strategies depending on the availability of voxel-based equieffective dose calculation and visualization tools. Selection of an assessment strategy should balance clinical resources with patient-specific considerations. Calculation and visualization of equieffective dose distributions facilitate cumulative dose assessment and strengthen image registration-based methods. If 3-dimensional equieffective dose calculation is not available, anatomically corresponding volumes and doses in each plan contributing to the cumulative dose in the areas of overlap can be determined manually to improve the accuracy of point dose-based summation. CONCLUSIONS: The case examples demonstrate how to apply the ReCOG consensus for dosimetric assessment and reporting in reRT and illustrate multiple strategies for cumulative dose evaluation. This work supports patient care and contributes to enhancing the field's knowledge and delivery of safer reRT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiation Oncology, The University of Michigan, Ann Arbor, Michigan. Electronic address: zhclaire@med.umich.edu.
- Department of Radiation Oncology, The University of Michigan, Ann Arbor, Michigan.
- BC Cancer-Prince George, Department of Radiation Oncology, Prince George, British Columbia, Canada.
- Department of Radiation Oncology, Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Gliwice, Poland.
- Department of Radiation Oncology, Bon Secours Mercy Health System, Youngstown, Ohio.
- Department of Medical Physics, Aarhus University Hospital and Department of Clinical Medicine, Faculty of Health Sciences, Aarhus University, Aarhus, Denmark.
Förderung
- Siemens
Zitieren
APA
Zhang, C., Mayo, C. S., Matrosic, C. K., Chang, D. T., Chng, N., Dess, R. T., Evans, J. R., Gabryś, D., Heron, D. E., Hoffmann, L., Jackson, W. C., Matuszak, M. M., Prisciandaro, J. I., Rosen, B. S., Salerno, K. E., Simone, C. B., Xiao, Y., & Paradis, K. C. (2026). A Case-Based Guide: Demonstrating the Reirradiation Collaborative Group (ReCOG) Consensus for Dosimetric Assessment and Reporting in Reirradiation. Practical Radiation Oncology, 16(6), e553-e563. https://doi.org/10.1016/j.prro.2026.03.010
Vancouver
Zhang C, Mayo CS, Matrosic CK, Chang DT, Chng N, Dess RT, et al. A Case-Based Guide: Demonstrating the Reirradiation Collaborative Group (ReCOG) Consensus for Dosimetric Assessment and Reporting in Reirradiation. Practical Radiation Oncology. 2026;16(6):e553-e563. doi:10.1016/j.prro.2026.03.010
BibTeX
@article{Zhang2026,
author = {Zhang, Claire and Mayo, Charles S and Matrosic, Charles K and Chang, Daniel T and Chng, Nick and Dess, Robert T and Evans, Joseph R and Gabryś, Dorota and Heron, Dwight E and Hoffmann, Lone and Jackson, William C and Matuszak, Martha M and Prisciandaro, Joann I and Rosen, Benjamin S and Salerno, Kilian E and Simone, Charles B and Xiao, Ying and Paradis, Kelly C},
title = {A Case-Based Guide: Demonstrating the Reirradiation Collaborative Group (ReCOG) Consensus for Dosimetric Assessment and Reporting in Reirradiation},
journal = {Practical Radiation Oncology},
year = {2026},
volume = {16},
number = {6},
pages = {e553--e563},
doi = {10.1016/j.prro.2026.03.010}
}
EUVIMED