Abutment screw preload verification: Calculation using tightening torque, loosening torque, and screw thread pitch versus actual measurement
The Journal of Prosthetic Dentistry · 2026-11 · 136 (5) · e23-e29
DOI: 10.1016/j.prosdent.2026.08.017 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-11. Verfasst von Chandur P K Wadhwani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Private practice, Bellevue, Wash,; and Affiliate Assistant Professor, Department of Restorative Dentistry, University of Washington School of Dentist…. Hauptthemen laut MEDLINE: Dental Abutments, Dental Implant-Abutment Design. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Quantifying abutment screw preload is essential in determining the risk of premature screw loosening. Currently, this is complex, requiring sophisticated measuring devices. A simplified methodology for calculating abutment screw preload has recently been proposed, but a comprehensive evaluation of its validity is lacking. PURPOSE: The purpose of this in vitro study was to determine the validity of the dental implant screw preload calculation for accuracy and precision by comparing the calculated method with direct load cell measurements. MATERIAL AND METHODS: Six implant-abutment assemblies underwent preload measurement assessed using a specialized load cell. The implant abutment screw was tightened to 35 Ncm, using an electronic torque device. The screws were then loosened and the reverse torque recorded. Each assembly underwent 10 tightening and reverse torque cycles such that the screw preload was zero. Recorded data, along with screw thread pitch size, were used to calculate preload using the screw equation. Measured versus calculated preload provided percentage differences, linear regression model, Bland-Altman analysis, and concordance correlation coefficients were assessed for validation (α=.05). RESULTS: Linear regression analysis revealed a significant positive correlation across all groups (R2=.67 to .89, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Private practice, Bellevue, Wash,; and Affiliate Assistant Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash. Electronic address: cpkw1@live.com.
- Professor, Department of Mechanical Engineering, University of South Florida, Tampa, Fla.
- Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, Ga.
- Professor Emeritus, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.
- Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.
Zitieren
APA
Wadhwani, C. P. K., Hess, D. P., Schoenbaum, T. R., Rubenstein, J. E., & Chung, K. H. (2026). Abutment screw preload verification: Calculation using tightening torque, loosening torque, and screw thread pitch versus actual measurement. The Journal of Prosthetic Dentistry, 136(5), e23-e29. https://doi.org/10.1016/j.prosdent.2026.08.017
Vancouver
Wadhwani CPK, Hess DP, Schoenbaum TR, Rubenstein JE, Chung KH. Abutment screw preload verification: Calculation using tightening torque, loosening torque, and screw thread pitch versus actual measurement. The Journal of Prosthetic Dentistry. 2026;136(5):e23-e29. doi:10.1016/j.prosdent.2026.08.017
BibTeX
@article{Wadhwani2026,
author = {Wadhwani, Chandur P K and Hess, Daniel P and Schoenbaum, Todd R and Rubenstein, Jeffrey E and Chung, Kwok-Hung},
title = {Abutment screw preload verification: Calculation using tightening torque, loosening torque, and screw thread pitch versus actual measurement},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {136},
number = {5},
pages = {e23--e29},
doi = {10.1016/j.prosdent.2026.08.017}
}
EUVIMED