EUVIMEDEUVIMED entdecken
Crossref

Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body–independent technique

Mohamed Sherif Omar, Toshiki Nagai

The Journal of Prosthetic Dentistry · 2026-11 · 136 (5) · 1241-1247

DOI: 10.1016/j.prosdent.2026.07.026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-11. Verfasst von Mohamed Sherif Omar und 1 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Assistant Professor, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind; and Director of Digital Innova…. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Abutments, Dental Prosthesis, Implant-Supported, Dental Implant-Abutment Design. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate measurement of interimplant distances and angulations is essential for evaluating implant scanning workflows in implant-supported complete arch fixed dental prostheses. Current methods such as root mean square (RMS) surface deviation and geometric primitive fitting do not capture these relationships directly: RMS lacks implant-specific localization, while geometric fitting remains operator- and geometry-dependent. A scan body-independent technique for measuring interimplant distances and angulations directly from computer-aided design-generated multiunit abutment bottom components is described. An open-source program (DIME: Direct Implant Measurement and Evaluation) was used to extract coordinates and axes from corresponding components and reports per-implant deviations and pairwise interimplant relationships. Demonstration included controlled-displacement validation on a synthetic dataset and application across digital recording workflows with different scan body geometries. By measuring the fitting surface used for framework fabrication, the method captures implant spatial data complementary to existing accuracy-evaluation approaches.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignDental AbutmentsDental Prosthesis, Implant-SupportedDental Implant-Abutment DesignHumansDental Implants

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Clinical Assistant Professor, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind; and Director of Digital Innovation Lab, Indiana University School of Dentistry, Indianapolis, Ind.
  • Clinical Assistant Professor, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind. Electronic address: tnagai@iu.edu.

Zitieren

APA

Omar, M. S., & Nagai, T. (2026). Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body–independent technique. The Journal of Prosthetic Dentistry, 136(5), 1241-1247. https://doi.org/10.1016/j.prosdent.2026.07.026

Vancouver

Omar MS, Nagai T. Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body–independent technique. The Journal of Prosthetic Dentistry. 2026;136(5):1241-1247. doi:10.1016/j.prosdent.2026.07.026

BibTeX
@article{Omar2026,
  author = {Omar, Mohamed Sherif and Nagai, Toshiki},
  title = {Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body–independent technique},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {136},
  number = {5},
  pages = {1241--1247},
  doi = {10.1016/j.prosdent.2026.07.026}
}
Kostenlos starten →