Influence of pulp chamber geometry and intraoral scanner on the accuracy of one-piece endodontic crown preparation scans
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2026.05.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Hamiyet Güngör und 4 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Department of Prosthetic Dentistry, Lokman Hekim University, Ankara, Turkey. Electronic address: gngr.hamiyet@gmail.com. Hauptthemen laut MEDLINE: Dental Pulp Cavity, Crowns, Computer-Aided Design, Dental Prosthesis Design. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Intraoral scanners (IOSs) have been widely used for the digital fabrication of 1-piece endodontic crowns, but the effect of pulp chamber geometry associated with chamber depth and axial wall configuration on scan accuracy performed with different IOSs is not yet clear. PURPOSE: The purpose of this in vitro study was to evaluate the influence of pulp chamber design and IOS type on the accuracy of digital scans for 1-piece endodontic crown preparations. MATERIAL AND METHODS: Four experimental models (A3, A5, NA3, and NA5) were prepared with 2 pulp chamber depths (3 and 5 mm) and 2 axial wall configurations (with or without axial walls). Each model was scanned 11 times with 2 different IOSs (TRIOS 5; 3Shape and iTero Element 5D; Align Technology), yielding 88 scans. A metrology-grade desktop scanner was used to obtain reference scans. Trueness was assessed via the 3-dimensional (3D) comparison (Geomagic Control X 2022.3;3D Systems) of reference scans and test scans by using the root mean square (RMS) method. Two-way nonparametric factorial analysis of variance ANOVA with the aligned-rank transform (ART) was used to examine the effects of factors and their interactions. Post hoc pairwise comparisons were performed using the estimated marginal means (EMMs) of the aligned ranks with Bonferroni correction (α=.05). RESULTS: Pulp chamber geometry associated with chamber depth and axial wall configuration-scanner combinations led to significant differences in scan trueness (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Assistant Professor, Department of Prosthetic Dentistry, Lokman Hekim University, Ankara, Turkey. Electronic address: gngr.hamiyet@gmail.com.
- PhD student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
- Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
- Visiting Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and Associate Professor, Department of Prosthodontics, School of Dentistry…
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric D…
Zitieren
APA
Güngör, H., Galvao, C. S., Carreiro, A. D. F. P., Yoon, H. I., & Yılmaz, B. (2026). Influence of pulp chamber geometry and intraoral scanner on the accuracy of one-piece endodontic crown preparation scans. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.05.018
Vancouver
Güngör H, Galvao CS, Carreiro ADFP, Yoon HI, Yılmaz B. Influence of pulp chamber geometry and intraoral scanner on the accuracy of one-piece endodontic crown preparation scans. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.05.018
BibTeX
@article{Gngr2026,
author = {Güngör, Hamiyet and Galvao, Cecilia Santos and Carreiro, Adriana da Fonte Porto and Yoon, Hyung-In and Yılmaz, Burak},
title = {Influence of pulp chamber geometry and intraoral scanner on the accuracy of one-piece endodontic crown preparation scans},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2026.05.018}
}
EUVIMED