Effect of implant number and spatial configuration on reverse torque values of screw-retained restorations after mechanical aging: An in vitro study
The Journal of Prosthetic Dentistry · 2026-08 · 136 (2) · e228-e234
DOI: 10.1016/j.prosdent.2026.03.048 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-08. Verfasst von Athanasios Stratos und 7 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Instructor, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessalonik…. Hauptthemen laut MEDLINE: Dental Implants, Dental Prosthesis, Implant-Supported, Dental Prosthesis Retention. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Screw loosening has been observed in screw-retained multiunit implant prostheses. The effects of implant number, spatial configuration, and screw position on preload retention remain unclear. PURPOSE: The purpose of this in vitro study was to compare the reverse torque values and torque-loss patterns after mechanical aging in screw-retained prostheses on different numbers of implants and configurations. MATERIAL AND METHODS: Thirty screw-retained, implant-supported cobalt chromium (Remanium Star Co-Cr powder; Dentaurum GmbH & Co KG) framework specimens were fabricated by laser sintering, fastened on multiunit abutments (EL OMNI; Century Technologies S.R.L.), and randomly assigned to 3 groups comprised of 2 parallel implants (15×3.8 mm ΕL; Century Technologies S.R.L.) placed 10-mm apart, 4 parallel implants placed in a straight line with 10 mm spacing, and 4 parallel implants with an anteroposterior spread, with the 2 distal segments in 45-degree angulation. The prosthetic screws (SSR-ASC; Century Technologies S.R.L.) were tightened to 20 Ncm, and initial values were recorded. Mechanical aging followed (1 200 000 cycles, 70 N, 60 mm/second, dry conditions) with vertical loading via a 2-mm-rounded pin. Final reverse torque values and percentage torque loss were calculated relative to 20 Ncm. The primary analysis was the torque loss of the 2 screws adjacent to the load across all groups, and the secondary analysis was the force distribution patterns. Data were analyzed using 2-way repeated-measures ANOVA with post hoc comparisons. RESULTS: Torque loss was highest at load-adjacent screws, with 2-implant prostheses showing 36.0% and 27.5% loss, straight 4-implant prostheses 23.5%, 13.5%, 8.5%, and 4.5% from the loaded to contralateral screws, and anteroposterior spread 4-implant prostheses 20.0%, 11.0%, 15.0%, and 4.0%. P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Clinical Instructor, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece. Electronic address: stratosathanasios@hotmail.com.
- Postgraduate Resident, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
- Private practice, Thessaloniki, Greece.
- Master Dental Technologist, Department of Dental Technology, University of West Attica, Athens, Greece; and Goethe Dental School, Goethe University of Frankfurt, Frankfurt, Germany.
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece; and Adjunct Assistant Professor, Department of Prosthodonti…
- Associate Professor and Chair, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Zitieren
APA
Stratos, A., Niakou, A., Rodiou, S., Moutsios, A., Kamalakidis, S. N., Tortopidis, D., Michalakis, P., & Pissiotis, A. (2026). Effect of implant number and spatial configuration on reverse torque values of screw-retained restorations after mechanical aging: An in vitro study. The Journal of Prosthetic Dentistry, 136(2), e228-e234. https://doi.org/10.1016/j.prosdent.2026.03.048
Vancouver
Stratos A, Niakou A, Rodiou S, Moutsios A, Kamalakidis SN, Tortopidis D, et al. Effect of implant number and spatial configuration on reverse torque values of screw-retained restorations after mechanical aging: An in vitro study. The Journal of Prosthetic Dentistry. 2026;136(2):e228-e234. doi:10.1016/j.prosdent.2026.03.048
BibTeX
@article{Stratos2026,
author = {Stratos, Athanasios and Niakou, Athina and Rodiou, Stylianos and Moutsios, Alexander and Kamalakidis, Savvas N and Tortopidis, Dimitrios and Michalakis, Polychronis and Pissiotis, Argirios},
title = {Effect of implant number and spatial configuration on reverse torque values of screw-retained restorations after mechanical aging: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {136},
number = {2},
pages = {e228--e234},
doi = {10.1016/j.prosdent.2026.03.048}
}
EUVIMED