EUVIMEDEUVIMED entdecken
Vergleichsstudie

Acceptability, deviation, and efficiency of 2 fully automated CAD software programs in designing 3-unit fixed dental prostheses: A comparative study

Kedith Sawangsri, Mariam Bekkali, Yuan-Lynn Hsieh, Yi-Cheng Lai, Yudanur Ucar, Hanin S Hammoudeh

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2025.11.034 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Kedith Sawangsri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio. Elect…. Hauptthemen laut MEDLINE: Computer-Aided Design, Software, Dental Prosthesis Design, Denture, Partial, Fixed. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Fully automated artificial intelligence (AI)-based computer-aided design (CAD) software programs have shown promise for single-unit crown design, but their accuracy, acceptability, and efficiency in designing multi-unit fixed dental prostheses (FDPs) remain unclear. PURPOSE: This in vitro study evaluated the design acceptability, trueness, and efficiency of 2 commercially available fully automated AI -based CAD software programs in designing anterior and posterior 3-unit FDPs compared with those designed by dental laboratory technicians. MATERIAL AND METHODS: Digital scans of natural abutments prepared for 3-unit fixed dental prostheses (12 anterior and 18 posterior FDPs) were replicated into 3 sets and allocated for restoration design by Certified Dental Technician (CDT), dentbird (DB), and Atomica AI (AA). Restoration designs were evaluated qualitatively using an 11-criteria acceptability score by 3 calibrated prosthodontists and quantitatively using root mean square (RMS) deviation analysis. CAD times were recorded for each group. Statistical analyses included the Kruskal-Wallis test followed by the Dunn post hoc test, paired t test, and repeated-measure ANOVA followed by the paired t test to evaluate intergroup differences (α=.05). RESULTS: DB successfully generated all designs (100%), while AA achieved a 93% overall success rate (83% for anterior and 100% posterior FDPs). AA obtained acceptability scores comparable with those of CDT, particularly in posterior FDPs, while DB exhibited significantly lower scores, especially in anterior FPDs. Both AI programs scored lower than CDT in occlusal and proximal contact areas and connector size (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignSoftwareDental Prosthesis DesignDenture, Partial, FixedDenture DesignHumansArtificial IntelligenceCrownsIn Vitro Techniques

Autor:innen und Institutionen

  • Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio. Electronic address: sawangsri.1@osu.edu.
  • Resident, Advanced Prosthodontic Program, The Ohio State University College of Dentistry, Columbus, Ohio.
  • Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
  • Clinical Assistant Associate Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio; and Retired Professor, Department of Prosthetic Dentistry, Cukuro…
  • Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio; and Scholar, College of Dentistry, University of Jordan, Amman, Jordan.

Zitieren

APA

Sawangsri, K., Bekkali, M., Hsieh, Y. L., Lai, Y. C., Ucar, Y., & Hammoudeh, H. S. (2026). Acceptability, deviation, and efficiency of 2 fully automated CAD software programs in designing 3-unit fixed dental prostheses: A comparative study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.11.034

Vancouver

Sawangsri K, Bekkali M, Hsieh YL, Lai YC, Ucar Y, Hammoudeh HS. Acceptability, deviation, and efficiency of 2 fully automated CAD software programs in designing 3-unit fixed dental prostheses: A comparative study. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2025.11.034

BibTeX
@article{Sawangsri2026,
  author = {Sawangsri, Kedith and Bekkali, Mariam and Hsieh, Yuan-Lynn and Lai, Yi-Cheng and Ucar, Yudanur and Hammoudeh, Hanin S},
  title = {Acceptability, deviation, and efficiency of 2 fully automated CAD software programs in designing 3-unit fixed dental prostheses: A comparative study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2025.11.034}
}
Kostenlos starten →