EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Accuracy of pin-supported surgical guides for complete arch implant placement: A comparison with conventional mucosa-supported guides

Yu Jen Chen, Yuqing Lu, Jiayi Lu, Fei Liu, Berna Saglik, Sandra H Stuhr, Junying Li

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2025.11.006 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Yu Jen Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Prosthodontic Resident, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbo…. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Dental Implantation, Endosseous. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: American Academy of Fixed Prosthodontics.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: While static computer-assisted implant surgery (sCAIS) has improved implant placement accuracy in edentulous arches, mucosa-supported sCAIS guides present limitations, including a lack of direct visualization and irrigation. A novel design for pin-supported sCAIS guides has been developed to address these issues, but its accuracy compared with that of mucosa-supported sCAIS guides remains unclear. PURPOSE: The purpose of this in vitro study was to compare the accuracy of implant placement achieved with pin-supported and mucosa-supported sCAIS guides using standardized edentulous maxillary models. MATERIAL AND METHODS: Twenty-four identical edentulous maxillary models were divided into 2 groups (n=12). The mucosa-supported group underwent fully guided implant placement using mucosa-supported sCAIS guides with a flapless protocol. The pin-supported group used a 2-guide pin-supported sCAIS protocol with flap elevation, with 6 implants being planned and placed per model. After implant placement, scan bodies were attached, and the models were scanned. Deviations between planned and actual implant positions were measured using the Blender software program and custom Python scripts. A linear mixed model was used to compare mean deviations between groups (α=.05, with Bonferroni correction for multiple comparisons). RESULTS: The pin-supported group demonstrated statistically higher deviations across most parameters, including coronal global (0.89 ±0.36 mm versus 0.72 ±0.305 mm), apical global (1.22 ±0.47 mm versus 0.97 ±0.43 mm), coronal horizontal (0.63 ±0.36 mm versus 0.48 ±0.23 mm), apical horizontal (1.01 ±0.51 mm versus 0.77 ±0.44 mm), and angular deviations (2.84 ±1.33 degrees versus 2.03 ±1.03 degrees), compared with the mucosa-supported group (P .05). All mean deviations remained within clinically acceptable limits (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousHumansMaxillaIn Vitro TechniquesJaw, EdentulousDental Implants

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Graduate Prosthodontic Resident, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
  • Research Fellow, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.; and Assistant Professor, Department of Reconstructive Oral Care, Academic Ce…
  • Research Fellow, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
  • Professor, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
  • Clinical Professor, Department of Biologic and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
  • Clinical Assistant Professor, Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Mich.

Förderung

  • American Academy of Fixed Prosthodontics

Zitieren

APA

Chen, Y. J., Lu, Y., Lu, J., Liu, F., Saglik, B., Stuhr, S. H., & Li, J. (2025). Accuracy of pin-supported surgical guides for complete arch implant placement: A comparison with conventional mucosa-supported guides. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.11.006

Vancouver

Chen YJ, Lu Y, Lu J, Liu F, Saglik B, Stuhr SH, et al. Accuracy of pin-supported surgical guides for complete arch implant placement: A comparison with conventional mucosa-supported guides. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.11.006

BibTeX
@article{Chen2025,
  author = {Chen, Yu Jen and Lu, Yuqing and Lu, Jiayi and Liu, Fei and Saglik, Berna and Stuhr, Sandra H and Li, Junying},
  title = {Accuracy of pin-supported surgical guides for complete arch implant placement: A comparison with conventional mucosa-supported guides},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2025.11.006}
}
Kostenlos starten →