EUVIMEDEUVIMED entdecken
Systematische ÜbersichtÜbersichtsarbeit

Clinical and patient-reported outcomes of implant-retained overdentures fabricated by digital and conventional workflows: A systematic review of clinical studies

Lucas Cavalcante de Sousa, Pamela Tayná Matias Bezerra, João Vitor do Nascimento Santos, Ji-Man Park, Rodrigo Othávio de Assunção E Souza, Adriana da Fonte Porto Carreiro

The Journal of Prosthetic Dentistry · 2026-05 · 135 (5) · e43-e52

DOI: 10.1016/j.prosdent.2025.10.013 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-05. Verfasst von Lucas Cavalcante de Sousa und 5 weiteren Autor:innen. Beteiligte Einrichtung: PhD student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil. Hauptthemen laut MEDLINE: Denture, Overlay, Dental Prosthesis, Implant-Supported, Computer-Aided Design, Patient Reported Outcome Measures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Coordination for the improvement of Higher Education Personnel.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Digital workflows have been used to fabricate implant-retained overdentures (IODs). However, a systematic review evaluating the clinical performance and patient-related outcome measures (PROMs) of computer-aided design and computer-aided manufacturing (CAD-CAM) IODs is still lacking. PURPOSE: The purpose of this systematic review was to compare the clinical performance and patient-related outcomes of implant-retained overdentures fabricated using digital and conventional techniques. MATERIAL AND METHODS: A comprehensive search was conducted in February 2025 across 4 electronic databases: PubMed/MEDLINE, Scopus, Embase, and Web of Science. Clinical studies comparing CAD-CAM and conventional workflows for the fabrication of IODs were included. Eligible studies reported on clinical outcomes and/or PROMs. Studies not involving direct comparison between the 2 fabrication methods or lacking relevant clinical data were excluded. RESULTS: From 322 studies identified, 9 were included in this review. Of these, 7 studies examined clinical performance (prosthetic complications, implant and overdenture success and survival rates, maximum occlusal force, masticatory performance, tissue surface adaptation, retention, and deformation) and 5 studies investigated PROMs (general and oral health-related quality of life and patient satisfaction). Overall, the included studies indicated that CAD-CAM IODs resulted in fewer prosthetic complications, favorable implant and overdenture survival, improved function, and similar or greater PROMs compared with conventional IODs. CONCLUSIONS: CAD-CAM IODs were found to have overall superior clinical performance and similar or better patient-related outcomes when compared with conventional ones.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, OverlayDental Prosthesis, Implant-SupportedComputer-Aided DesignPatient Reported Outcome MeasuresWorkflowDental Prosthesis DesignDenture DesignHumans

Autor:innen und Institutionen

  • PhD student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
  • Associate Professor, Department of Prosthodontics & Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.
  • Associate Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
  • Associate Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil. Electronic address: adriana.carreiro@ufrn.br.

Förderung

  • Coordination for the improvement of Higher Education Personnel

Zitieren

APA

Sousa, L. C., Bezerra, P. T. M., Santos, J. V. D. N., Park, J. M., de Assunção E Souza, R. O., & Carreiro, A. D. F. P. (2026). Clinical and patient-reported outcomes of implant-retained overdentures fabricated by digital and conventional workflows: A systematic review of clinical studies. The Journal of Prosthetic Dentistry, 135(5), e43-e52. https://doi.org/10.1016/j.prosdent.2025.10.013

Vancouver

Sousa LC, Bezerra PTM, Santos JVDN, Park JM, de Assunção E Souza RO, Carreiro ADFP. Clinical and patient-reported outcomes of implant-retained overdentures fabricated by digital and conventional workflows: A systematic review of clinical studies. The Journal of Prosthetic Dentistry. 2026;135(5):e43-e52. doi:10.1016/j.prosdent.2025.10.013

BibTeX
@article{Sousa2026,
  author = {Sousa, Lucas Cavalcante de and Bezerra, Pamela Tayná Matias and Santos, João Vitor do Nascimento and Park, Ji-Man and de Assunção E Souza, Rodrigo Othávio and Carreiro, Adriana da Fonte Porto},
  title = {Clinical and patient-reported outcomes of implant-retained overdentures fabricated by digital and conventional workflows: A systematic review of clinical studies},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {135},
  number = {5},
  pages = {e43--e52},
  doi = {10.1016/j.prosdent.2025.10.013}
}
Kostenlos starten →