EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study

Lucas Ferreira, Ana Ribeiro, Pierre-Hadrien Decaup

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2025.08.038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Lucas Ferreira und 2 weiteren Autor:innen. Beteiligte Einrichtung: Master's student, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France. Hauptthemen laut MEDLINE: Dental Articulators. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Université de Bordeaux.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The reproducibility of positioning the maxillary occlusal plane in an articulator with a facebow remains debated. Its clinical use is widespread, yet its reliability and clinical outcomes compared to other transfer methods under standardized conditions remain uncertain. PURPOSE: The purpose of this in vitro study was to compare the intra-operator reproducibility of maxillary positioning on an articulator using a facebow compared to a standardized transfer table. MATERIAL AND METHODS: Sixty identical maxillary replicas from a single patient were mounted by a single operator (30 using a facebow and 30 using a 10-degree inclined transfer table). Each articulator was scanned, and frontal and sagittal occlusal plane angulations were measured using a validated mesh-based method. Statistical analyses included Shapiro-Wilk test to assess normality, Fligner-Killeen and Wilcoxon rank-sum tests to compare the groups, and Cliff δ to estimate effect size. RESULTS: The mesh-based analysis was validated with perfect intra-observer agreement. The reproducibility significantly differed for both frontal and sagittal inclinations between the facebow record and the standardized method (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ArticulatorsHumansReproducibility of ResultsMaxillaObserver VariationJaw Relation RecordIn Vitro Techniques

Autor:innen und Institutionen

  • Master's student, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France.
  • Assistant Lecturer, Department of Paediatric Dentistry, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France; and Associate Researcher, University of Bordeaux, CNRS, Ministry of Culture, PACE…
  • Assistant Professor, Department of Prosthetic Dentistry, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France; and Researcher, University of Bordeaux, CNRS, Ministry of Culture, PACEA, UMR 51…

Förderung

  • Université de Bordeaux

Zitieren

APA

Ferreira, L., Ribeiro, A., & Decaup, P. H. (2025). Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.08.038

Vancouver

Ferreira L, Ribeiro A, Decaup PH. Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.08.038

BibTeX
@article{Ferreira2025,
  author = {Ferreira, Lucas and Ribeiro, Ana and Decaup, Pierre-Hadrien},
  title = {Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2025.08.038}
}
Kostenlos starten →