Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems and a noncalibrated splinting technique: A clinical study
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2025.07.027 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Marta Revilla-León und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Different implant scanning techniques can be used to capture the position of the implants being restored, including intraoral and extraoral photogrammetry (PG) systems and noncalibrated splinting methods. However, clinical studies that have analyzed the accuracy these implant scanning techniques are sparse. PURPOSE: The purpose of this clinical study was to assess the trueness and precision of complete arch implant scans captured by using 2 extraoral and an intraoral PG system and a noncalibrated splinting technique. MATERIAL AND METHODS: A patient with a maxillary edentulous arch with 4 osseointegrated implants participated in the study. Each implant had an implant abutment (SRA RB Abutment). To obtain the reference file (control), an optical marker (iCam4D scan body) was hand tightened on each implant abutment, and 10 consecutive PG scans were obtained by using a calibrated extraoral PG system (iCam4D). Four groups were created depending on the system used to capture the position of the implants: Grammee, MicronMapper, Elite, and IOConnect (n=10). In the Grammee group, the corresponding optical marker was tightened on each implant abutment and PG scans were recorded by using the camera of the extraoral PG system. In the MicronMapper group, an optical marker of the extraoral PG device was hand tightened on each implant abutment, and PG scans were recorded by using the camera of the system. In the Elite group, scan bodies were hand tightened on the implant abutments, and intraoral scans were captured by using the corresponding intraoral scanner (IOS) (Aoralscan Elite). Euclidean linear and angular measurements were calculated on the 10 reference scans, and the average of each was used to compare the discrepancies with the same measurements obtained on each experimental scan. One-way ANOVA and Tukey post hoc tests were used to analyze the trueness data. The Levene test was used to analyze the precision values (α=.05). RESULTS: Significant linear trueness discrepancies were found among the groups (P .05). Additionally, statistically significant angular trueness differences were revealed among the groups (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
- Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spa…
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Private practice, Valparaiso, Ind.
- Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
- Associate Professor Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
Zitieren
APA
Revilla-León, M., Cascos, R., Barmak, A. B., Drone, M., Kois, J. C., & Gómez-Polo, M. (2026). Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems and a noncalibrated splinting technique: A clinical study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.07.027
Vancouver
Revilla-León M, Cascos R, Barmak AB, Drone M, Kois JC, Gómez-Polo M. Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems and a noncalibrated splinting technique: A clinical study. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2025.07.027
BibTeX
@article{RevillaLen2026,
author = {Revilla-León, Marta and Cascos, Rocio and Barmak, Abdul B and Drone, Michael and Kois, John C and Gómez-Polo, Miguel},
title = {Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems and a noncalibrated splinting technique: A clinical study},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2025.07.027}
}
EUVIMED