EUVIMEDEUVIMED entdecken
Crossref

Alignment accuracy of soft tissue and implant position scans captured by using four intraoral scanners and an intraoral photogrammetry system with and without coded healing abutments

Marta Revilla-León, Rocio Cascos, Abdul B Barmak, John C Kois, Miguel Gómez-Polo

The Journal of Prosthetic Dentistry · 2025-10 · 134 (4) · 1259.e1-1259.e10

DOI: 10.1016/j.prosdent.2025.06.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-10. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Photogrammetry, Dental Abutments, Dental Implants, Dental Implantation, Endosseous. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The registration accuracy of the soft tissue and implant position scans of an implant scanning workflow recorded by using conventional intraoral scanners (IOSs) or an intraoral photogrammetry (PG) system with or without coded healing abutments (CHAs) remains unknown. PURPOSE: The purpose of this in vitro study was to assess the registration accuracy of the soft tissue and implant position scans recorded by using four IOSs and 1 intraoral PG system with or without CHAs. MATERIAL AND METHODS: An edentulous stone cast with 6 implant abutment analogs was acquired. Three markers were adhered to the palatal surface of the cast. A healing abutment was hand tightened into each implant abutment, and the cast was scanned (T710) (control). Six groups were created: Lumina, TRIOS 5, Primescan, i700, Elite without CHA, and Elite with CHAs (n=15). Except for the Elite with CHAs group, soft tissue scans were obtained from the cast by using the corresponding IOS. The healing abutments were retrieved, and a horizontal implant scan body (ISB) (IOConnect) was hand tightened into each implant abutment of the cast. Except for the Elite groups, implant position scans were captured by using the corresponding IOS. Then, the ISBs were retrieved from the cast. In the Elite groups, a PG ISB (Intraoral Photogrammetry Scan Body) was hand tightened into each implant abutment of the cast and implant position scans were recorded. In the Elite without CHAs, the soft tissue and implant scans were aligned by recording a bilateral record. The PG ISBs were retrieved. Lastly, in the Elite with CHAs, a CHA (Smart Healing Cup) was hand tightened into each implant abutment of the cast and soft tissue scans were recorded. In the Elite with CHAs, the soft tissue and implant scans were automatically aligned by the IOS program. Except for the specimens of the Elite groups, the soft tissue and implant position scans were aligned (DentalCAD). All the registered scans were imported into another program (Geomagic), and the measurement point of each implant abutment geometry was located (intersection between the longitudinal axis and the apical z-plane). Eighteen linear measurements were performed between the markers and measurement points in the control scan and each specimen. Trueness was analyzed using 1-way ANOVA and the Tukey tests, and precision was evaluated using the Levene test (α=.05). RESULTS: The mean ±standard deviation differences of the registration of soft tissue and implant position scans ranged from 98 ±28 µm to 127 ±29 µm. One-way ANOVA demonstrated significant trueness discrepancies among the groups (P=.044). The Tukey test revealed that the Elite with CHAs group obtained significantly better trueness than the i700 group (P=.046). The Levene test showed no significant precision discrepancies among the groups tested (P=.084). CONCLUSIONS: The IOS system used to register the soft tissue and implant position scans affected the trueness of the registration procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryDental AbutmentsDental ImplantsDental Implantation, EndosseousHumansIn Vitro TechniquesDental Implant-Abutment Design

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
  • Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics Program, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Mad…
  • Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
  • Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
  • Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.

Zitieren

APA

Revilla-León, M., Cascos, R., Barmak, A. B., Kois, J. C., & Gómez-Polo, M. (2025). Alignment accuracy of soft tissue and implant position scans captured by using four intraoral scanners and an intraoral photogrammetry system with and without coded healing abutments. The Journal of Prosthetic Dentistry, 134(4), 1259.e1-1259.e10. https://doi.org/10.1016/j.prosdent.2025.06.015

Vancouver

Revilla-León M, Cascos R, Barmak AB, Kois JC, Gómez-Polo M. Alignment accuracy of soft tissue and implant position scans captured by using four intraoral scanners and an intraoral photogrammetry system with and without coded healing abutments. The Journal of Prosthetic Dentistry. 2025;134(4):1259.e1-1259.e10. doi:10.1016/j.prosdent.2025.06.015

BibTeX
@article{RevillaLen2025,
  author = {Revilla-León, Marta and Cascos, Rocio and Barmak, Abdul B and Kois, John C and Gómez-Polo, Miguel},
  title = {Alignment accuracy of soft tissue and implant position scans captured by using four intraoral scanners and an intraoral photogrammetry system with and without coded healing abutments},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  volume = {134},
  number = {4},
  pages = {1259.e1--1259.e10},
  doi = {10.1016/j.prosdent.2025.06.015}
}
Kostenlos starten →