EUVIMEDEUVIMED entdecken
Crossref

Bland-Altman analysis of maxillary obturator bulb accuracy in class III Brown classification maxillectomy defects

Shady M El Naggar, Mohamed Adel Youssef Abdelsalam, Youssef M Eissa, Sherihan M Eissa

The Journal of Prosthetic Dentistry · 2026

DOI: 10.1016/j.prosdent.2025.04.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Shady M El Naggar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor of Removable Prosthodontics, Faculty of Dentistry, Benha National University, Obour City, Egypt. Electronic address: shady.elnagg…. Hauptthemen laut MEDLINE: Palatal Obturators, Maxilla, Dental Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Maxillofacial tumor resection leads to major functional and esthetic issues that adversely affect patients' quality of life. Obturators have been used to manage issues such as hypernasality and fluid leakage. However, their adaptation to maxillary defects and patient comfort requires further study. Understanding how material composition influences obturator retention, durability, and long-term satisfaction is essential for optimizing prosthetic design. PURPOSE: The purpose of this nonrandomized, self-controlled study was to compare the accuracy and patient satisfaction of polymethyl methacrylate (PMMA) bulbs on metal frameworks and flexible injection-molded resin bulbs. MATERIAL AND METHODS: Two obturator types were evaluated. Type PMMA-BMF used PMMA bulbs on metal frameworks, while Type FIMR used flexible injection-molded resin bulbs. Adaptation was assessed using 3-dimensional (3D) scanning and superimposition techniques, with root mean square (RMS) values and average positive and negative deviations as key metrics using the Bland-Altman analysis of agreement with bias ±standard deviation calculated and plotted (95% limits of agreement). Patient satisfaction was evaluated using the obturator functioning scale (OFS) domains. RESULTS: Type PMMA-BMF obturators showed significantly higher RMS and average positive and negative deviations than Type FIMR (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Palatal ObturatorsMaxillaDental Prosthesis DesignHumansPatient SatisfactionPolymethyl MethacrylateFemaleMaleMiddle AgedMaxillary NeoplasmsAdult

Substanzen

Polymethyl Methacrylate

Autor:innen und Institutionen

  • Assistant Professor of Removable Prosthodontics, Faculty of Dentistry, Benha National University, Obour City, Egypt. Electronic address: shady.elnaggar@den.bnu.edu.eg.
  • Assistant Lecturer of Oral Radiology, Faculty of Oral and Dental Medicine, Badr University in Cairo, Cairo, Egypt.
  • Resident of Otolaryngology, Faculty of Medicine, Cairo University, Cairo, Egypt.
  • Assistant Professor of Removable Prosthodontics, Fixed and Removable Prosthodontics Department, Oral and Dental Research Institute, National Research Centre, Cairo, Egypt.

Zitieren

APA

El Naggar, S. M., Abdelsalam, M. A. Y., Eissa, Y. M., & Eissa, S. M. (2026). Bland-Altman analysis of maxillary obturator bulb accuracy in class III Brown classification maxillectomy defects. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.04.014

Vancouver

El Naggar SM, Abdelsalam MAY, Eissa YM, Eissa SM. Bland-Altman analysis of maxillary obturator bulb accuracy in class III Brown classification maxillectomy defects. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2025.04.014

BibTeX
@article{ElNaggar2026,
  author = {El Naggar, Shady M and Abdelsalam, Mohamed Adel Youssef and Eissa, Youssef M and Eissa, Sherihan M},
  title = {Bland-Altman analysis of maxillary obturator bulb accuracy in class III Brown classification maxillectomy defects},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  doi = {10.1016/j.prosdent.2025.04.014}
}
Kostenlos starten →