EUVIMEDEUVIMED entdecken
Crossref

Influence of scan extension on the accuracy of maximum intercuspal position recorded by using intraoral scanners or an artificial intelligence-based program

Marta Revilla-León, Miguel Gómez-Polo, Abdul B Barmak, John C Kois, Jorge Alonso Pérez-Barquero

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2025.01.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Artificial Intelligence, Dental Occlusion. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) and artificial intelligence (AI) based programs can be used to locate the maximum intercuspal position (MIP). However, the influence of scan extension on the accuracy of the MIP located by using these technologies is uncertain. PURPOSE: The purpose of this in vitro study was to analyze the effect of scan extension on the accuracy of the MIP located by using 3 IOSs and an AI-based program. MATERIAL AND METHODS: Stone casts mounted in an articulator in MIP were digitized (T710). Two groups were created: complete- (CA group) and half arch (HA group) scan. In the CA-group, complete arch scans of the reference casts were captured with each IOS tested. The nonarticulated scans were duplicated 20 times. In the HA-groups, the right half arch scans of the reference casts were captured with each IOS tested. Six subgroups were generated: 3 IOS (Primescan-IOS, i700-IOS, and Aoralscan3-IOS) and 3 AI (Primescan-AI, i700-AI, and Aoralscan3-AI) subgroups. In the CA-Primescan-IOS subgroup, 10 duplicated scans were articulated in MIP by recording a bilateral occlusal record. In the CA-Primescan-AI subgroup, 10 duplicated scans were articulated in MIP by using an AI-based program (Bitefinder). In the CA-i700-IOS, CA-Aoralscan3-IOS, CA-i700-AI, and CA-Aoralscan3-AI subgroups, the same procedures as in the CA-Primescan-IOS and CA-Primescan-AI subgroups were completed, respectively. In the HA-Primescan-IOS subgroup, 10 duplicated scans were articulated in MIP by capturing a right occlusal record. In the HA-Primescan-AI subgroup, 10 duplicated scans were articulated in MIP by using the AI-based program. In the HA-i700-IOS, HA-Aoralscan3-IOS, HA-i700-AI, and HA-Aoralscan3-AI subgroups, the same procedures as in the HA-Primescan-IOS subgroups were completed, respectively. A program (Geomagic) was used to calculate 36 interlandmark measurements on the virtual articulated casts (control) and each specimen. Three-way ANOVA and Tukey tests were used to analyze trueness (α=.05). The Levene and pairwise multiple comparison tests were used to analyze precision (α=.05). RESULTS: MIP trueness discrepancies were found between the IOS (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceDental OcclusionHumansModels, DentalIn Vitro TechniquesImage Processing, Computer-AssistedJaw Relation Record

Autor:innen und Institutionen

  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director of Research and Digital Dentistry, Kois Cen…
  • Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
  • Associate Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
  • Founder and Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; and Private Practice,…
  • Associate Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.

Zitieren

APA

Revilla-León, M., Gómez-Polo, M., Barmak, A. B., Kois, J. C., & Alonso Pérez-Barquero, J. (2025). Influence of scan extension on the accuracy of maximum intercuspal position recorded by using intraoral scanners or an artificial intelligence-based program. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.01.012

Vancouver

Revilla-León M, Gómez-Polo M, Barmak AB, Kois JC, Alonso Pérez-Barquero J. Influence of scan extension on the accuracy of maximum intercuspal position recorded by using intraoral scanners or an artificial intelligence-based program. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.01.012

BibTeX
@article{RevillaLen2025,
  author = {Revilla-León, Marta and Gómez-Polo, Miguel and Barmak, Abdul B and Kois, John C and Alonso Pérez-Barquero, Jorge},
  title = {Influence of scan extension on the accuracy of maximum intercuspal position recorded by using intraoral scanners or an artificial intelligence-based program},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2025.01.012}
}
Kostenlos starten →