Effect of simulated gastric acid exposure on the hardness, topographic, and colorimetric properties of machinable and pressable zirconia-reinforced lithium silicate glass-ceramics
The Journal of Prosthetic Dentistry · 2024
DOI: 10.1016/j.prosdent.2024.06.021 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Abdulaziz Alhotan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia. Hauptthemen laut MEDLINE: Zirconium, Ceramics, Surface Properties, Gastric Acid. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Saud University.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The effects of gastric acid on the hardness, topographic, and colorimetric properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remain unknown. PURPOSE: The purpose of this in vitro study was to investigate the effect of simulated gastric acid exposure on the microhardness, surface roughness, color stability, and relative translucency of ZLSs. MATERIAL AND METHODS: Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD)(n=64) were randomly allocated to artificial saliva (control) or gastric juice immersion groups simulating 10 and 20 years of clinical exposure. Microhardness (Hv) was measured with a Vickers hardness device, and surface roughness (Sa) was recorded with an optical profilometer. The color stability (ΔE00) and relative translucency parameter (RTP) were measured with a spectrophotometer. Data for Hv, Sa, and RTP were analyzed by repeated 2-way ANOVA, and data for ΔE00 were analyzed by 2-way ANOVA. Post hoc comparisons were obtained from Tukey HSD and Student t tests (α=.05). RESULTS: Machinable ZLSs exhibited greater Hv after the simulated gastric acid challenge than pressable ZLSs. Sa was significantly impacted by material type (P=.001), storage media (P=.050), and their interaction (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
- Assistant Professor, Department of Periodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
- PhD student, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK. Electronic address: hamaljuhani1@kau.edu.sa.
- Dental Intern, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
Förderung
- King Saud University
Zitieren
APA
Alhotan, A., Alaqeely, R., Al-Johani, H., Alrobaish, S., & Albaiz, S. (2024). Effect of simulated gastric acid exposure on the hardness, topographic, and colorimetric properties of machinable and pressable zirconia-reinforced lithium silicate glass-ceramics. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.06.021
Vancouver
Alhotan A, Alaqeely R, Al-Johani H, Alrobaish S, Albaiz S. Effect of simulated gastric acid exposure on the hardness, topographic, and colorimetric properties of machinable and pressable zirconia-reinforced lithium silicate glass-ceramics. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.06.021
BibTeX
@article{Alhotan2024,
author = {Alhotan, Abdulaziz and Alaqeely, Razan and Al-Johani, Hanan and Alrobaish, Shahad and Albaiz, Sarah},
title = {Effect of simulated gastric acid exposure on the hardness, topographic, and colorimetric properties of machinable and pressable zirconia-reinforced lithium silicate glass-ceramics},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
doi = {10.1016/j.prosdent.2024.06.021}
}
EUVIMED