Biocompatibility of polymethyl methacrylate heat-polymerizing denture base resin copolymerized with antimicrobial monomers
The Journal of Prosthetic Dentistry · 2024
DOI: 10.1016/j.prosdent.2024.06.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Sowmya Rao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Reader, Department of Dental Materials, Yenepoya Dental College, Yenepoya (Deemed to be University), Mangalore 575018, Karnataka, India. Electronic a…. Hauptthemen laut MEDLINE: Biocompatible Materials, Polymethyl Methacrylate, Acrylic Resins, Dentures. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Quaternary ammonium (QA)-based monomers such as dimethyl-hexadecyl-methacryloxyethyl-ammonium iodide (DHMAI) and 2-dimethyl-2-dodecyl-1-methacryloxyethyl ammonium iodine (DDMAI) have been investigated as copolymerizable monomers to impart antimicrobial activity to dental restorative and prosthetic materials. However, the biocompatibility of these antimicrobial monomers needs to be investigated in vivo before their clinical use. PURPOSE: The purpose of this study was to assess the in vivo biocompatibility of polymethyl methacrylate (PMMA) heat-polymerizing denture base resin copolymerized with varying concentrations of DHMAI and DDMAI. MATERIAL AND METHODS: The toxicity and genotoxicity of the antimicrobial monomers (DHMAI 5 µg/mL and DDMAI 20 µg/mL) at 1 to 100 µg/mL concentrations were investigated against zebrafish embryos (Danio rerio, n=10) using a zebrafish embryotoxicity test (ZET) or fish embryotoxicity test (FET) and comet assay, respectively. Further, DHMAI 5 µg/mL and DDMAI 20 µg/mL were incorporated into a conventional PMMA denture base system and a similar test was done on specimens of modified PMMA resin. For the evaluation of in vivo biocompatibility, modified PMMA specimens were subcutaneously implanted into Wistar rats (n=6) and biochemical, hematological, and histopathological parameters were investigated. Results were analyzed and compared using ANOVA and the Tukey post hoc test (α=.05). RESULTS: Toxicity and genotoxicity studies using zebrafish embryos revealed that the incorporation of monomer to PMMA did not increase the toxicity, as confirmed by post-hour fertilization. Modified PMMA did not affect the hematological parameters, such as red blood cell (RBC) and white blood cell (WBC) except for the platelet count, which was significantly increased (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Reader, Department of Dental Materials, Yenepoya Dental College, Yenepoya (Deemed to be University), Mangalore 575018, Karnataka, India. Electronic address: sowmyarao@yenepoya.edu.in.
- Consultant Veterinary Surgeon, Advanced Surgical Skill Enhancement Division (ASSEND), Yenepoya (Deemed to be University), Mangalore 575018, Karnataka, India.
- Research scholar, Yenepoya Research Centre, Yenepoya (Deemed to be University), Mangalore 575018, Karnataka, India.
- Professor, Department of Periodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai 600077, Tamil Nadu, India.
- Associate Professor, Yenepoya Research Centre, Yenepoya (Deemed to be University), Mangalore 575018, Karnataka, India.
- Professor, Department of Dental Materials, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India.
Zitieren
APA
Rao, S., Surya, S., S R, P., Ali, S., Prabhu, A., Ginjupalli, K., Shenoy, P. U., Das, R., & B T, N. (2024). Biocompatibility of polymethyl methacrylate heat-polymerizing denture base resin copolymerized with antimicrobial monomers. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.06.014
Vancouver
Rao S, Surya S, S R P, Ali S, Prabhu A, Ginjupalli K, et al. Biocompatibility of polymethyl methacrylate heat-polymerizing denture base resin copolymerized with antimicrobial monomers. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.06.014
BibTeX
@article{Rao2024,
author = {Rao, Sowmya and Surya, Suprith and S R, Pavan and Ali, Saheb and Prabhu, Ashwini and Ginjupalli, Kishore and Shenoy, Pooja Umesh and Das, Ranajit and B T, Nandish},
title = {Biocompatibility of polymethyl methacrylate heat-polymerizing denture base resin copolymerized with antimicrobial monomers},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
doi = {10.1016/j.prosdent.2024.06.014}
}
EUVIMED