Evaluating the effects of splinting implant scan bodies intraorally on the trueness of complete arch digital scans: A clinical study

Kawther Ali, Abdulaziz A Alzaid, Montry S Suprono, Antoanela Garbacea, Roberto Savignano, Mathew T Kattadiyil

The Journal of Prosthetic Dentistry · 2024

DOI: 10.1016/j.prosdent.2024.03.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Kawther Ali und 5 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Department of Restorative Sciences, Faculty of Dentistry, Kuwait University Health Sciences Center, Jabriya, Kuwait. Electronic …. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Loma Linda University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: A predictable protocol for accurately scanning implants in a complete edentulous arch has not been established. PURPOSE: The purpose of this clinical study was to investigate the effect of splinting implant scan bodies intraorally on the accuracy and scan time for digital scans of edentulous arches. MATERIAL AND METHODS: This single center, nonrandomized, clinical trial included a total of 19 arches. Definitive casts with scan bodies were fabricated and scanned with a laboratory scanner as the reference (control) scan. Each participant received 2 intraoral scans, the first with unsplinted scan bodies and the second with resin-splinted scan bodies. The scan time was also recorded for each scan. To compare the accuracy of the scans, the standard tessellation language (STL) files of the 2 scans were superimposed on the control scan, and positional and angular deviations were analyzed by using a 3-dimensional (3D) metrology software program. The Mann-Whitney U test was used to compare the distance and angular deviations between the splinted group and the unsplinted group with the control. The ANOVA test was conducted to examine the effect of the scan technique on trueness (distance deviation and angular deviation) and scan time (α=.05 for all tests). RESULTS: Statistically significant differences were found in the overall 3D positional and angular deviations of the unsplinted and splinted digital scans when compared with the reference scans (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalHumansDental ArchDental ImplantsComputer-Aided DesignJaw, EdentulousSplintsDental Impression TechniqueDental Prosthesis Design

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Assistant Professor, Department of Restorative Sciences, Faculty of Dentistry, Kuwait University Health Sciences Center, Jabriya, Kuwait. Electronic address: kawtheralberumi@gmail.com.
  • Assistant Professor, Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences and King Abdullah International Medical Research Center, Riyadh…
  • Associate Professor and Director, Center for Dental Research, School of Dentistry, Loma Linda University, Loma Linda, Calif.
  • Assistant Professor, Advanced Education Program in Prosthodontics and Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif.
  • Assistant Professor, Center for Dental Research, School of Dentistry, Loma Linda University, Loma Linda, Calif.
  • Professor and Director, Advanced Education Program in Prosthodontics, School of Dentistry, Loma Linda University, Loma Linda, Calif.

Förderung

  • Loma Linda University

Zitieren

APA

Ali, K., Alzaid, A. A., Suprono, M. S., Garbacea, A., Savignano, R., & Kattadiyil, M. T. (2024). Evaluating the effects of splinting implant scan bodies intraorally on the trueness of complete arch digital scans: A clinical study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.03.004

Vancouver

Ali K, Alzaid AA, Suprono MS, Garbacea A, Savignano R, Kattadiyil MT. Evaluating the effects of splinting implant scan bodies intraorally on the trueness of complete arch digital scans: A clinical study. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.03.004

BibTeX
@article{Ali2024,
  author = {Ali, Kawther and Alzaid, Abdulaziz A and Suprono, Montry S and Garbacea, Antoanela and Savignano, Roberto and Kattadiyil, Mathew T},
  title = {Evaluating the effects of splinting implant scan bodies intraorally on the trueness of complete arch digital scans: A clinical study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  doi = {10.1016/j.prosdent.2024.03.004}
}