Clinical efficacy of computer-assisted zygomatic implant surgery: A systematic scoping review
The Journal of Prosthetic Dentistry · 2025-10 · 134 (4) · 1062-1074
DOI: 10.1016/j.prosdent.2023.10.032 ↗Kurz gefasst
Scoping Review in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-10. Verfasst von Wenying Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, S…. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Dental Implants, Surgery, Computer-Assisted, Zygoma. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 70 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Digital technology can improve the success of zygomatic implant (ZI) surgery. However, the reliability and efficacy of computer-assisted zygomatic implant surgery (CAZIS) need further analysis. PURPOSE: The purpose of this scoping review was to provide an overview of the placement accuracy, implant survival, and complications of CAZIS. MATERIAL AND METHODS: A systematic search of English and Mandarin Chinese publications up to May 2023 was conducted in PubMed, Web of Science, Embase, and Wanfang database. The nonpeer-reviewed literature was searched in the trial register (clinicaltrials.gov). Clinical studies and cadaver studies on CAZIS were included. After data extraction and collection, the findings were critically reviewed, analyzed, interpreted, and discussed. RESULTS: Forty-one studies met the inclusion criteria. After excluding publications with duplicate data, retaining the most recent, 28 articles were included in this scoping review. Of these, 18 were on static computer-assisted zygomatic implant surgery (sCAZIS), 8 on dynamic computer-assisted zygomatic implant surgery (dCAZIS), and 2 on robot-assisted zygomatic implant surgery (rAZIS). Excluding the outliers, the mean deviations of ZIs in the sCAZIS group (with 8 articles reporting implant placement accuracy, 183 ZIs involved) were: 1.15 ±1.37 mm (coronal deviation), 2.29 ±1.95 mm (apical deviation), and 3.32 ±3.36 degrees (angular deviation). The mean deviations of dCAZIS (3 articles, 251 ZIs) were: 1.60 ±0.74 mm (coronal), 2.27 ±1.05 mm (apical), and 2.89 ±1.69 degrees (angular). The mean deviations of rAZIS (2 articles, 5 ZIs) were: 0.82 ±0.21 mm (coronal), 1.25 ±0.52 mm (apical), and 1.46 ±0.35 degrees (angular). Among the CAZIS reported in the literature, the implant survival rate was high (96.3% for sCAZIS, 98.2% for dCAZIS, and 100% for rAZIS, specified in 14 of 21 clinical studies). The incidence of complications was low, but, because of the few relevant studies (4/21 specified), valid conclusions regarding complications could not be drawn. CONCLUSIONS: CAZIS has demonstrated clinical efficacy with high implant survival rates and placement accuracy. Of the 3 guided approaches, rAZIS showed the smallest 3-dimensional deviation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Graduate student, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Nationa…
- Predoctoral student, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Nati…
- Professor, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clini…
Zitieren
APA
Wang, W., Yu, X., Wang, F., & Wu, Y. (2025). Clinical efficacy of computer-assisted zygomatic implant surgery: A systematic scoping review. The Journal of Prosthetic Dentistry, 134(4), 1062-1074. https://doi.org/10.1016/j.prosdent.2023.10.032
Vancouver
Wang W, Yu X, Wang F, Wu Y. Clinical efficacy of computer-assisted zygomatic implant surgery: A systematic scoping review. The Journal of Prosthetic Dentistry. 2025;134(4):1062-1074. doi:10.1016/j.prosdent.2023.10.032
BibTeX
@article{Wang2025,
author = {Wang, Wenying and Yu, Xinbo and Wang, Feng and Wu, Yiqun},
title = {Clinical efficacy of computer-assisted zygomatic implant surgery: A systematic scoping review},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
volume = {134},
number = {4},
pages = {1062--1074},
doi = {10.1016/j.prosdent.2023.10.032}
}
EUVIMED