EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Evaluation of the use of different intraoral scanners for auricular prosthetic reconstruction

Maged Ahmed Gadallah, Mohamed Moataz Khamis, Ahmed Mohamed Abdelhamid, Salah Ezzelarab

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2023.09.028 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Maged Ahmed Gadallah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Lecturer of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. Electronic address: maged.gad@alexu.edu.eg. Hauptthemen laut MEDLINE: Prosthesis Design, Imaging, Three-Dimensional, Ear, External. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The use of intraoral optical scanners has been introduced for direct digital data acquisition in maxillofacial prosthetics, but their clinical accuracy has not been evaluated sufficiently. PURPOSE: The purpose of this observational study was to evaluate the use of different intraoral scanners for extraoral maxillofacial digitization of an ear and to assess visually the clinical outcome of the generated 3-dimensional ear casts. MATERIAL AND METHODS: A selected intact ear was scanned by using 3 different intraoral optical scanners: CEREC Primescan (Dentsply Sirona), Medit i700 (Medit Corp) and Panda P2 (Pengtum Technologies). Three-dimensional printed auricular casts were fabricated from the obtained scans, and a questionnaire administered to assess visually the clinical outcome of the generated casts. Comparisons between scanners were done by using the Kruskal-Wallis test followed by the post hoc test with Bonferroni correction when results were significant. The Wilcoxon Sign Rank test was used to compare the responses of both the prosthodontists and the lay personnel. All tests were 2-tailed (α=.05). RESULTS: The 3-dimensional printed auricular casts fabricated from the data acquired by using Primescan and Medit i700 scanners showed a statistically significant difference in matching scores when compared with the Panda P2 scanner (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis DesignImaging, Three-DimensionalEar, ExternalHumansPrinting, Three-DimensionalComputer-Aided Design

Autor:innen und Institutionen

  • Assistant Lecturer of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. Electronic address: maged.gad@alexu.edu.eg.
  • Professor and Chairman, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
  • Professor of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Zitieren

APA

Gadallah, M. A., Khamis, M. M., Abdelhamid, A. M., & Ezzelarab, S. (2025). Evaluation of the use of different intraoral scanners for auricular prosthetic reconstruction. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2023.09.028

Vancouver

Gadallah MA, Khamis MM, Abdelhamid AM, Ezzelarab S. Evaluation of the use of different intraoral scanners for auricular prosthetic reconstruction. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2023.09.028

BibTeX
@article{Gadallah2025,
  author = {Gadallah, Maged Ahmed and Khamis, Mohamed Moataz and Abdelhamid, Ahmed Mohamed and Ezzelarab, Salah},
  title = {Evaluation of the use of different intraoral scanners for auricular prosthetic reconstruction},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2023.09.028}
}
Kostenlos starten →