Effect of simulated toothbrushing on the surface roughness of LOCATOR abutments: An in vitro study
The Journal of Prosthetic Dentistry · 2025-06 · 133 (6) · 1554-1559
DOI: 10.1016/j.prosdent.2023.08.026 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-06. Verfasst von Anna K Mcilwain und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Graduate Prosthodontics, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel H…. Hauptthemen laut MEDLINE: Toothbrushing, Dental Abutments, Denture, Overlay. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Studies evaluating the effect of toothbrushing and toothpaste abrasivity on the surface roughness of LOCATOR abutments are lacking. PURPOSE: The purpose of this in vitro study was to compare the surface roughness of LOCATOR abutments before and after simulated toothbrushing with different toothpastes to make recommendations for the home care of patients with LOCATOR abutments. MATERIAL AND METHODS: LOCATOR bone-level overdenture abutments (N=36) were analyzed with a confocal laser scanning microscope (Keyence VK-X1100) at ×5 magnification. Surface scans were made to determine the degree of surface roughness (Ra). Two toothpastes of different abrasivity (Colgate Total and Crest ProHealth) and deionized water were used as the brushing media (n=12). Each toothpaste was mixed with water in a 1:2 ratio. The abutments were brushed using soft nylon toothbrushes for 30 000 cycles in a ZM-3.12 toothbrushing simulator, which has been interpreted as 3 years of regular use. All specimens were then reanalyzed under the microscope. Changes in surface texture were compared by using a repeated measures analysis of variance (ANOVA) statistical test and a pairwise Šídák multiple comparisons test (α=.05). RESULTS: The mean surface roughness value of LOCATOR abutments at baseline ranged between 1.34 µm and 1.35 µm. After 30 000 cycles of toothbrushing simulation, the mean value increased to 1.62 µm (DI water, P=.001), 1.74 µm (Colgate Total, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Graduate student, Graduate Prosthodontics, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC.
- Oral and Craniofacial Biomedicine PhD student and Teaching Assistant, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC; Lecturer, Department…
- Assistant Professor, Prosthodontics, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC.
- Professor of Prosthodontics and Director for Clinical Curriculum, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC.
- Associate Professor, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC.. Electronic address: taiseer_sulaiman@unc.edu.
Zitieren
APA
Mcilwain, A. K., Alsahafi, T. A., Bashiri, R., Duqum, I., & Sulaiman, T. A. (2025). Effect of simulated toothbrushing on the surface roughness of LOCATOR abutments: An in vitro study. The Journal of Prosthetic Dentistry, 133(6), 1554-1559. https://doi.org/10.1016/j.prosdent.2023.08.026
Vancouver
Mcilwain AK, Alsahafi TA, Bashiri R, Duqum I, Sulaiman TA. Effect of simulated toothbrushing on the surface roughness of LOCATOR abutments: An in vitro study. The Journal of Prosthetic Dentistry. 2025;133(6):1554-1559. doi:10.1016/j.prosdent.2023.08.026
BibTeX
@article{Mcilwain2025,
author = {Mcilwain, Anna K and Alsahafi, Tariq A and Bashiri, Rafiullah and Duqum, Ibrahim and Sulaiman, Taiseer A},
title = {Effect of simulated toothbrushing on the surface roughness of LOCATOR abutments: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
volume = {133},
number = {6},
pages = {1554--1559},
doi = {10.1016/j.prosdent.2023.08.026}
}