Effect of print orientation, storage conditions, and storage time on intaglio surface accuracy of implant surgical guides fabricated by using a stereolithography technology
The Journal of Prosthetic Dentistry · 2025-07 · 134 (1) · 179-186
DOI: 10.1016/j.prosdent.2023.08.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-07. Verfasst von Alma L Salazar Rios und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Graduate Program in Prosthodontics, Comprehensive Dentistry Department, School of Dentistry, Texas A&M University, Dallas, Texas. Hauptthemen laut MEDLINE: Stereolithography, Printing, Three-Dimensional, Dental Prosthesis Design, Dental Implants. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The accuracy of printed implant surgical guides can be affected by different factors that negatively impact the planned implant position. How print orientation, storage time, and conditions influence manufacturing accuracy remains uncertain. PURPOSE: The purpose of this in vitro study was to evaluate the influence of print orientation, storage conditions, and storage time on the intaglio surface accuracy of implant surgical guides manufactured by using a stereolithography (SLA) printer. MATERIAL AND METHODS: A tooth-supported maxillary implant surgical guide design (control file) was used to fabricate the specimens (N=40, n=10). Four groups were created based on the print orientation used: 0 (Group 0), 45 (Group 45), 70 (Group 70), and 90 degrees (Group 90). The specimens were fabricated using an SLA printer (Form 3B+) and a biocompatible dental resin (Surgical Guide Resin V1) following the manufacturer's recommended protocol. Each group was divided into 2 subgroups based on the storage conditions: light (L subgroup) and dark (D subgroup) settings. Each specimen was digitized by using a desktop scanner (Medit T710) at days 0, 1, 7, and 14. The control file and each digitized specimen were superimposed by using the best-fit technique with a metrology program (Geomagic Control X). The root mean square (RMS) error was used to calculate the discrepancies between the control files and specimen files. Three-way ANOVA and pairwise comparison Tukey tests were used to analyze trueness. The Levene test was used to assess precision (α=.05). RESULTS: Significant trueness discrepancies were found among the groups tested (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Graduate student, Graduate Program in Prosthodontics, Comprehensive Dentistry Department, School of Dentistry, Texas A&M University, Dallas, Texas.
- Assistant Professor, Department of Orthodontics, School of Dentistry, Texas A&M University, Dallas, Texas.
- Adjunct Professor, Department of Periodontics, School of Dentistry, Texas A&M University, Dallas, Texas.
- Associate Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Clinical Professor and Director, Graduate Program in Prosthodontics, Comprehensive Dentistry Department, School of Dentistry, Texas A&M University, Dallas, Texas.
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director of Research and Digital Dentistry, Kois Cen…
Zitieren
APA
Salazar Rios, A. L., Kesterke, M. J., Pylant, G. D., Barmak, A. B., Kontogiorgos, E. D., & Revilla-León, M. (2025). Effect of print orientation, storage conditions, and storage time on intaglio surface accuracy of implant surgical guides fabricated by using a stereolithography technology. The Journal of Prosthetic Dentistry, 134(1), 179-186. https://doi.org/10.1016/j.prosdent.2023.08.016
Vancouver
Salazar Rios AL, Kesterke MJ, Pylant GD, Barmak AB, Kontogiorgos ED, Revilla-León M. Effect of print orientation, storage conditions, and storage time on intaglio surface accuracy of implant surgical guides fabricated by using a stereolithography technology. The Journal of Prosthetic Dentistry. 2025;134(1):179-186. doi:10.1016/j.prosdent.2023.08.016
BibTeX
@article{SalazarRios2025,
author = {Salazar Rios, Alma L and Kesterke, Matthew J and Pylant, George D and Barmak, Abdul B and Kontogiorgos, Elias D and Revilla-León, Marta},
title = {Effect of print orientation, storage conditions, and storage time on intaglio surface accuracy of implant surgical guides fabricated by using a stereolithography technology},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
volume = {134},
number = {1},
pages = {179--186},
doi = {10.1016/j.prosdent.2023.08.016}
}
EUVIMED