EUVIMEDEUVIMED entdecken
Crossref

Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study

Kenda I Hanno, Mohamed M Abdul-Monem

The Journal of Prosthetic Dentistry · 2023-11 · 130 (5) · 798.e1-798.e8

DOI: 10.1016/j.prosdent.2023.08.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2023-11. Verfasst von Kenda I Hanno und 1 weiteren Autor:innen. Beteiligte Einrichtung: Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt. Electronic address: kendahanno@gmail.com. Hauptthemen laut MEDLINE: Denture Cleansers, Denture Bases. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Studies on the impact of denture cleansers on the physical and mechanical properties of denture bases designed and constructed by using computer software programs are lacking. PURPOSE: The purpose of this in vitro study was to test the effect of a peroxide denture cleanser on the hardness, fracture toughness, water sorption, and solubility of denture base materials manufactured by 3D printing and computer-aided design and computer-aided manufacturing (CAD-CAM) milling. MATERIAL AND METHODS: The hardness, fracture toughness, water solubility, and sorption of CAD-CAM milled and 3D printed groups (n=40) were evaluated before and after exposure to a denture cleanser. Hardness (n=10) was analyzed with a Vickers hardness testing machine, and fracture toughness (n=20) with the 3-point bend test. After the fracture of specimens, a scanning electron microscope at ×300 was used for fractographic analysis. Water sorption and solubility (n=10) were evaluated before and after immersion in denture cleanser for 6 days to simulate 180 days of immersion. Two-way repeated ANOVA and 2-way ANOVA were used to test normally distributed data, whereas the Mann Whitney U test and Wilcoxon signed ranks test were used for data that were not normally distributed (α

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture CleansersDenture BasesMaterials TestingComputer-Aided DesignPrinting, Three-DimensionalWaterSurface Properties

Substanzen

Denture CleansersWater

Autor:innen und Institutionen

  • Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt. Electronic address: kendahanno@gmail.com.
  • Lecturer, Department of Dental Biomaterials, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt; Lecturer, Division of Dental Biomaterials, Department of Prosthodontics, Faculty of Dentistry, Alamein Inte…

Zitieren

APA

Hanno, K. I., & Abdul-Monem, M. M. (2023). Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study. The Journal of Prosthetic Dentistry, 130(5), 798.e1-798.e8. https://doi.org/10.1016/j.prosdent.2023.08.009

Vancouver

Hanno KI, Abdul-Monem MM. Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study. The Journal of Prosthetic Dentistry. 2023;130(5):798.e1-798.e8. doi:10.1016/j.prosdent.2023.08.009

BibTeX
@article{Hanno2023,
  author = {Hanno, Kenda I and Abdul-Monem, Mohamed M},
  title = {Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2023},
  volume = {130},
  number = {5},
  pages = {798.e1--798.e8},
  doi = {10.1016/j.prosdent.2023.08.009}
}
Kostenlos starten →