Risk factors associated with screw loosening in CAD-CAM custom abutments: A 6-year retrospective study
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2023.05.025 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Changmin Ju und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Department of Prosthodontics, Graduate School, School of Dentistry, Kyung Hee University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Restoration Failure, Dental Abutments, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Custom abutments made by using computer-aided design and computer-aided manufacturing (CAD-CAM) are often used for implant-supported prostheses. However, studies on screw loosening of implant prostheses using custom abutments are lacking. PURPOSE: The purpose of this retrospective study was to investigate the risk factors of screw loosening in implant-supported prostheses using custom abutments made with CAD-CAM. MATERIAL AND METHODS: Clinical charts, radiographic images, and CAD custom abutment design file data were collected and analyzed retrospectively. The study included 255 patients with 401 dental implants, and the follow-up duration was 6 years. Age, sex (male/female), type of unit (single-unit or multiunit), location of the implant (maxilla or mandible and anterior, premolar, or molar tooth), type of antagonist, and experience of the prosthodontist were reviewed, and implant angulation (mesiodistal and buccolingual), location of the screw access hole (mesiodistal and buccolingual distances from center), and attrition status (none, localized, or generalized) were measured by using a CAD file. The frequencies and percentages of risk factors were evaluated with the Fisher exact test, and the Bonferroni correction was used as a post hoc test. Multiple logistic regression with the Firth method was performed to calculate the odds ratios and their confidence intervals (α=.05). RESULTS: Screw loosening showed a correlation with the severity of attrition (P .05). CONCLUSIONS: The degree of attrition, buccolingual angulation of the implant and abutment, type of unit, and experience of the prosthodontist (>3 years or
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Graduate student, Department of Prosthodontics, Graduate School, School of Dentistry, Kyung Hee University, Seoul, Republic of Korea.
- Clinical Assistant Professor, Department of Prosthodontics, Kyung Hee University Dental Hospital, Seoul, Republic of Korea.
- Assistant Professor, College of Dentistry, Kyung Hee University, Seoul, Republic of Korea.
- Assistant Professor, College of Dental Medicine, Columbia University, New York, NY.
- Associate Professor, Department of Prosthodontics, College of Dentistry, Kyung Hee University, Seoul, Republic of Korea. Electronic address: paek217@gmail.com.
Zitieren
APA
Ju, C., Lee, Y., Hong, S. J., Song, S. J., Choi, Y., Cho, E., & Paek, J. (2025). Risk factors associated with screw loosening in CAD-CAM custom abutments: A 6-year retrospective study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2023.05.025
Vancouver
Ju C, Lee Y, Hong SJ, Song SJ, Choi Y, Cho E, et al. Risk factors associated with screw loosening in CAD-CAM custom abutments: A 6-year retrospective study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2023.05.025
BibTeX
@article{Ju2025,
author = {Ju, Changmin and Lee, Younghoo and Hong, Seoung-Jin and Song, Seung Jun and Choi, Youngkyun and Cho, Eunhan and Paek, Janghyun},
title = {Risk factors associated with screw loosening in CAD-CAM custom abutments: A 6-year retrospective study},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2023.05.025}
}
EUVIMED