Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements
The Journal of Prosthetic Dentistry · 2024-11 · 132 (5) · 1067.e1-1067.e8
DOI: 10.1016/j.prosdent.2023.04.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-11. Verfasst von Mustafa Borga Donmez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; and Visiting Researcher, Department of…. Hauptthemen laut MEDLINE: Titanium, Composite Resins, Resin Cements, Dental Bonding. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Additively manufactured composite resins for definitive restorations have been recently introduced. The bond strength between these composite resins and different substrates has not been extensively studied. PURPOSE: The purpose of this in vitro study was to measure the shear bond strength (SBS) between additively manufactured composite resins and dentin and titanium substrates and compare those with the SBS between subtractively manufactured polymer-infiltrated ceramic and the same substrates (dentin and titanium), when different dual-polymerizing resin cements were used. MATERIAL AND METHODS: One hundred and eighty cylinder-shaped specimens (Ø5×5 mm) were prepared from 3 materials recommended for definitive restorations: an additively manufactured composite resin (Crowntec [CT]); an additively manufactured hybrid composite resin (VarseoSmile Crown Plus [VS]); and a subtractively manufactured polymer-infiltrated ceramic (Enamic [EN]) (n=60). Specimens were randomly divided into six subgroups to be cemented to the two substrates (dentin and titanium; n=30) with 1 of 3 resin cements (RelyX Universal, Panavia V5, and Variolink Esthetic DC) (n=10). The restoration surface to be bonded was treated according to the respective manufacturer's recommendations. Dentin surfaces were treated according to the resin cement (Scotchbond Universal Plus Adhesive for RelyX Universal, Panavia V5 Tooth Primer for Panavia V5, and Adhese Universal for Variolink Esthetic DC), while titanium surfaces were airborne-particle abraded, and only the specimens paired with Panavia V5 were treated with a ceramic primer (Clearfil Ceramic Primer Plus). SBS was measured in a universal testing machine at a crosshead speed of 1 mm/min. Failure modes were analyzed under a microscope at ×12 magnification. Data were analyzed by using 2-way analysis of variance and Tukey honestly significant difference tests (α=.05). RESULTS: When SBS to dentin was considered, only restorative material, as a main factor, had a significant effect (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; and Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine…
- Senior Resarch Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey.
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and External Research Associate, Division of Gerodontology and Removable Pr…
- Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric D…
Zitieren
APA
Donmez, M. B., Çakmak, G., Yılmaz, D., Schimmel, M., Abou-Ayash, S., Yilmaz, B., & Peutzfeldt, A. (2024). Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements. The Journal of Prosthetic Dentistry, 132(5), 1067.e1-1067.e8. https://doi.org/10.1016/j.prosdent.2023.04.003
Vancouver
Donmez MB, Çakmak G, Yılmaz D, Schimmel M, Abou-Ayash S, Yilmaz B, et al. Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements. The Journal of Prosthetic Dentistry. 2024;132(5):1067.e1-1067.e8. doi:10.1016/j.prosdent.2023.04.003
BibTeX
@article{Donmez2024,
author = {Donmez, Mustafa Borga and Çakmak, Gülce and Yılmaz, Deniz and Schimmel, Martin and Abou-Ayash, Samir and Yilmaz, Burak and Peutzfeldt, Anne},
title = {Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {132},
number = {5},
pages = {1067.e1--1067.e8},
doi = {10.1016/j.prosdent.2023.04.003}
}
EUVIMED