EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of artificial intelligence-designed single-molar dental prostheses: A feasibility study

Reinhard Chun Wang Chau, Richard Tai-Chiu Hsung, Colman McGrath, Edmond Ho Nang Pow, Walter Yu Hang Lam

The Journal of Prosthetic Dentistry · 2024-06 · 131 (6) · 1111-1117

DOI: 10.1016/j.prosdent.2022.12.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-06. Verfasst von Reinhard Chun Wang Chau und 4 weiteren Autor:innen. Beteiligte Einrichtung: Research Assistant, Restorative Dental Sciences, Faculty of Dentistry, the University of Hong Kong, Hong Kong Special Administrative Region, PR China. Hauptthemen laut MEDLINE: Feasibility Studies, Computer-Aided Design, Artificial Intelligence, Dental Prosthesis Design. Die Arbeit wurde bisher 84-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) technology has greatly improved the efficiency of the fabrication of dental prostheses. However, the design process (CAD stage) is still time-consuming and labor intensive. PURPOSE: The purpose of this feasibility study was to investigate the accuracy of a novel artificial intelligence (AI) system in designing biomimetic single-molar dental prostheses by comparing and matching them to the natural molar teeth. MATERIAL AND METHODS: A total of 169 maxillary casts were obtained from healthy dentate participants. The casts were digitized, duplicated, and processed with the removal of the maxillary right first molar. A total of 159 pairs of original and processed casts were input into the Generative Adversarial Networks (GANs) for training. In validation, 10 sets of processed casts were input into the AI system, and 10 AI-designed teeth were generated through backpropagation. Individual AI-designed teeth were then superimposed onto each of the 10 original teeth, and the morphological differences in mean Hausdorff distance were measured. True reconstruction was defined as correct matching between the AI-designed and original teeth with the smallest mean Hausdorff distance. The ratio of true reconstruction was calculated as the Intersection-over-Union. The reconstruction performance of the AI system was determined by the Hausdorff distance and Intersection-over-Union. RESULTS: Data of validation showed that the mean Hausdorff distance ranged from 0.441 to 0.752 mm and the Intersection-over-Union of the system was 0.600 (60%). CONCLUSIONS: This study demonstrated the feasibility of AI in designing single-molar dental prostheses. With further training and optimization of algorithms, the accuracy of biomimetic AI-designed dental prostheses could be further enhanced.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Feasibility StudiesComputer-Aided DesignArtificial IntelligenceDental Prosthesis DesignMolarHumansDental ProsthesisModels, DentalAdult

Autor:innen und Institutionen

  • Research Assistant, Restorative Dental Sciences, Faculty of Dentistry, the University of Hong Kong, Hong Kong Special Administrative Region, PR China.
  • Associate Professor, Department of Computer Science, Chu Hai College of Higher Education, Hong Kong Special Administrative Region, PR China; Honorary Associate Professor, Discipline of Oral and Maxillofacial Surgery, Fa…
  • Clinical Professor in Dental Public Health and Division Coordinator of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, the University of Hong Kong, Hong Kong Special Administrative Region, PR Chin…
  • Clinical Associate Professor in Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, the University of Hong Kong, Hong Kong Special Administrative Region, PR China.
  • Clinical Assistant Professor in Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, the University of Hong Kong, Hong Kong Special Administrative Region, PR China; Founding Member, Musketeers Foundation I…

Zitieren

APA

Chau, R. C. W., Hsung, R. T., McGrath, C., Pow, E. H. N., & Lam, W. Y. H. (2024). Accuracy of artificial intelligence-designed single-molar dental prostheses: A feasibility study. The Journal of Prosthetic Dentistry, 131(6), 1111-1117. https://doi.org/10.1016/j.prosdent.2022.12.004

Vancouver

Chau RCW, Hsung RT, McGrath C, Pow EHN, Lam WYH. Accuracy of artificial intelligence-designed single-molar dental prostheses: A feasibility study. The Journal of Prosthetic Dentistry. 2024;131(6):1111-1117. doi:10.1016/j.prosdent.2022.12.004

BibTeX
@article{Chau2024,
  author = {Chau, Reinhard Chun Wang and Hsung, Richard Tai-Chiu and McGrath, Colman and Pow, Edmond Ho Nang and Lam, Walter Yu Hang},
  title = {Accuracy of artificial intelligence-designed single-molar dental prostheses: A feasibility study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  volume = {131},
  number = {6},
  pages = {1111--1117},
  doi = {10.1016/j.prosdent.2022.12.004}
}
Kostenlos starten →