Evaluation of two different occlusal patterns on single posterior implant-supported crowns: A 12-month prospective study of occlusal analysis
The Journal of Prosthetic Dentistry · 2024
DOI: 10.1016/j.prosdent.2022.11.026 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Ru Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Attending, Department of Prosthodontics, Capital Medical University School of Stomatology, Beijing Stomatological Hospital, Beijing, PR China. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Crowns, Dental Occlusion, Dental Implants, Single-Tooth. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: According to the concept of implant-protected occlusion, light occlusion and late contact could prevent implants from occlusal overload. However, clinical data demonstrating how light occlusion differs from normal occlusion are lacking. PURPOSE: The purpose of this prospective clinical study was to characterize the occlusal variation of single posterior implant-supported crowns with or without light occlusion. MATERIAL AND METHODS: Participants with a single missing posterior maxillary or mandibular molar who were to receive implant-supported zirconia ceramic crowns were enrolled. The participants were divided into a light occlusion group, in which a 12-μm articulating film could be removed from the implant-supported crown and opposing natural teeth under the intercuspal position, and a normal occlusion group, in which the articulating film could not be removed. All participants underwent occlusal examinations using the T-scan III system, answered a satisfaction questionnaire using a visual analog scale (VAS), and received regular follow-ups. The participants were evaluated at 0.5, 3, 6, and 12 months after implant-supported crown delivery. The relative occlusal force of the implant-supported crowns, mesial teeth, control teeth (corresponding natural tooth on the dentition contralateral to each implant), and the occlusal contact time of implant-supported crowns were recorded. Moreover, the asymmetry index of the occlusal force and the VAS score were calculated. Two independent-sample tests were used to compare the 2 groups. The Wilcoxon rank sum and Mann‒Whitney tests were used to compare nonnormally distributed data (α=.001). RESULTS: Fifty study participants with a mean ±standard deviation age of 36.97 ±7.34 years (23 men and 27 women aged 20 to 50 years) were followed for 0.5 to 12 months. No obvious complications of overloading were observed in either group. The mean ±standard deviation of the relative occlusal force of implant-supported crowns in the light occlusion group (from 4.91 ±3.52% to 10.34 ±4.35%) was always lower than that in the normal occlusion group (from 10.45 ±4.32% to 18.15 ±4.80%), while the mean ±standard deviation of the occlusal contact time in the light occlusion group (from 0.38 ±0.26 seconds to 0.10 ±0.07 seconds) was significantly later than that in the normal occlusion group (from 0.12 ±0.08 seconds to 0.04 ±0.02 seconds) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Attending, Department of Prosthodontics, Capital Medical University School of Stomatology, Beijing Stomatological Hospital, Beijing, PR China.
- Graduate Student, Department of Prosthodontics, Capital Medical University School of Stomatology, Beijing Stomatological Hospital, Beijing, PR China.
- Associate Chief, Department of Oral and Maxillofacial Surgery, Capital Medical University School of Stomatology, Beijing Stomatological Hospital, Beijing, PR China. Electronic address: zhang-kaiy@263.net.
Zitieren
APA
Zhang, R., Hao, X., & Zhang, K. (2024). Evaluation of two different occlusal patterns on single posterior implant-supported crowns: A 12-month prospective study of occlusal analysis. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2022.11.026
Vancouver
Zhang R, Hao X, Zhang K. Evaluation of two different occlusal patterns on single posterior implant-supported crowns: A 12-month prospective study of occlusal analysis. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2022.11.026
BibTeX
@article{Zhang2024,
author = {Zhang, Ru and Hao, Xiaoyu and Zhang, Kaiyu},
title = {Evaluation of two different occlusal patterns on single posterior implant-supported crowns: A 12-month prospective study of occlusal analysis},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
doi = {10.1016/j.prosdent.2022.11.026}
}
EUVIMED