Accuracy, scanning time, and number of photograms of various scanning patterns for the extraoral digitalization of complete dentures by using an intraoral scanner

Miguel Gómez-Polo, Augusto Cimolai, Rocío Ortega, Abdul B Barmak, John C Kois, Marta Revilla-León

The Journal of Prosthetic Dentistry · 2024-03 · 131 (3) · 521-528

DOI: 10.1016/j.prosdent.2022.03.017 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-03. Verfasst von Miguel Gómez-Polo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor Department of Conservative Dentistry and Prosthodontics, Director of Postgraduate Program of Advanced in Implant-Prosthodontics, …. Hauptthemen laut MEDLINE: Denture, Complete, Mandible. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The use of intraoral scanners (IOSs) has been described as a method of digitizing complete dentures (CDs) extraorally; however, accuracy, scanning time, and number of photograms remain unclear. PURPOSE: The purpose of this in vitro study was to assess the accuracy, scanning time, and number of photograms of different scanning patterns for digitizing CDs extraorally with an IOS. MATERIAL AND METHODS: The virtual design of a maxillary and mandibular CD was used to manufacture milled CDs. The maxillary (Mx group) and mandibular (Mb group) CDs were digitized extraorally by using an IOS (Medit i500). Three subgroups were created depending on the scanning pattern: using the protocol of the IOS selected (Medit Link) (ML subgroup), using the technique recommended by the implant manufacturer (DIOnavi) (DIO subgroup), and using a custom method (C subgroup). The design of the CDs (reference files) was used to compare the discrepancy between each virtual design and the corresponding scans by using the root mean square (RMS) error. The scanning time and number of photograms were recorded. Two-way ANOVA and Tukey tests were used to analyze the trueness data. The Bartlett test was used to analyze the precision values (α=.05). RESULTS: The group (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, CompleteMandibleAnalysis of VarianceResearch Design

Autor:innen und Institutionen

  • Associate Professor Department of Conservative Dentistry and Prosthodontics, Director of Postgraduate Program of Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.…
  • Postgraduate student of Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
  • Adjunct Professor, Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, Madrid, Spain.
  • Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
  • Founder and Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Private practice, Seattl…
  • Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Af…

Zitieren

APA

Gómez-Polo, M., Cimolai, A., Ortega, R., Barmak, A. B., Kois, J. C., & Revilla-León, M. (2024). Accuracy, scanning time, and number of photograms of various scanning patterns for the extraoral digitalization of complete dentures by using an intraoral scanner. The Journal of Prosthetic Dentistry, 131(3), 521-528. https://doi.org/10.1016/j.prosdent.2022.03.017

Vancouver

Gómez-Polo M, Cimolai A, Ortega R, Barmak AB, Kois JC, Revilla-León M. Accuracy, scanning time, and number of photograms of various scanning patterns for the extraoral digitalization of complete dentures by using an intraoral scanner. The Journal of Prosthetic Dentistry. 2024;131(3):521-528. doi:10.1016/j.prosdent.2022.03.017

BibTeX
@article{GmezPolo2024,
  author = {Gómez-Polo, Miguel and Cimolai, Augusto and Ortega, Rocío and Barmak, Abdul B and Kois, John C and Revilla-León, Marta},
  title = {Accuracy, scanning time, and number of photograms of various scanning patterns for the extraoral digitalization of complete dentures by using an intraoral scanner},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  volume = {131},
  number = {3},
  pages = {521--528},
  doi = {10.1016/j.prosdent.2022.03.017}
}