EUVIMEDEUVIMED entdecken
Systematische ÜbersichtVergleichsstudie

CAD-CAM glass fiber compared with conventional prefabricated glass fiber posts: A systematic review

Tiago S Costa, Ruana M R Brandão, Bruna C Farias Vajgel, Juliana R SoutoMaior

The Journal of Prosthetic Dentistry · 2024-08 · 132 (2) · 337-342

DOI: 10.1016/j.prosdent.2022.01.007 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-08. Verfasst von Tiago S Costa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Predoctoral student, School of Dentistry, Federal University of Pernambuco (UFPE), Recife, Pernambuco, Brazil. Hauptthemen laut MEDLINE: Glass, Computer-Aided Design, Post and Core Technique. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: A prefabricated glass fiber post provides esthetic and biomechanical benefits for severely damaged endodontically treated teeth; however, failures in post retention remain a challenge. PURPOSE: The purpose of this systematic review was to compare the fracture resistance and bond strength of prefabricated glass fiber posts to those made with computer-aided design and computer-aided manufacturing (CAD-CAM). MATERIAL AND METHODS: This review was entered into PROSPERO (CRD42020213668) and was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Electronic systematic searches of PubMed/MEDLINE, Embase, and the Cochrane Library were conducted for published articles until October 2020. Studies that compared prefabricated glass fiber posts with CAD-CAM-fabricated glass fiber posts were selected, and studies that had not been published in English or in the previous 10 years were excluded. The fracture resistance (N) and bond strength (MPa) were the primary outcomes. RESULTS: After reviewing the title, abstract, and the entire text of 227 articles, 8 studies were selected. Four studies were omitted. Four of the 8 studies were retained for qualitative analyses, with 1 having a high risk of bias and 3 having a medium risk of bias. Only 1 study found significantly higher fracture resistance in the CAD-CAM group than in the prefabricated group. The bond strength study reported a significant difference, with the CAD-CAM group having greater bond strength than the prefabricated group. CONCLUSIONS: Despite the high heterogeneity and the few included articles, a tendency was found for the CAD-CAM-fabricated glass fiber post to improve fracture resistance and bond strength. However, the available literature is insufficient to draw definitive conclusions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlassComputer-Aided DesignPost and Core TechniqueHumansDental Prosthesis DesignDental Restoration FailureTooth, Nonvital

Substanzen

fiberglass

Autor:innen und Institutionen

  • Predoctoral student, School of Dentistry, Federal University of Pernambuco (UFPE), Recife, Pernambuco, Brazil.
  • Master's Degree student, Department of Prosthesis and Oral-Facial Surgery, Federal University of Pernambuco (UFPE), Recife, Pernambuco, Brazil.
  • Adjunct Professor, Department of Prosthesis and Oral-Facial Surgery, Federal University of Pernambuco (UFPE), Recife, Pernambuco, Brazil.
  • Adjunct Professor, Department of Prosthesis and Oral-Facial Surgery, Federal University of Pernambuco (UFPE), Recife, Pernambuco, Brazil. Electronic address: juliana.maior@ufpe.br.

Zitieren

APA

Costa, T. S., Brandão, R. M. R., Farias Vajgel, B. C., & SoutoMaior, J. R. (2024). CAD-CAM glass fiber compared with conventional prefabricated glass fiber posts: A systematic review. The Journal of Prosthetic Dentistry, 132(2), 337-342. https://doi.org/10.1016/j.prosdent.2022.01.007

Vancouver

Costa TS, Brandão RMR, Farias Vajgel BC, SoutoMaior JR. CAD-CAM glass fiber compared with conventional prefabricated glass fiber posts: A systematic review. The Journal of Prosthetic Dentistry. 2024;132(2):337-342. doi:10.1016/j.prosdent.2022.01.007

BibTeX
@article{Costa2024,
  author = {Costa, Tiago S and Brandão, Ruana M R and Farias Vajgel, Bruna C and SoutoMaior, Juliana R},
  title = {CAD-CAM glass fiber compared with conventional prefabricated glass fiber posts: A systematic review},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  volume = {132},
  number = {2},
  pages = {337--342},
  doi = {10.1016/j.prosdent.2022.01.007}
}
Kostenlos starten →