EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparing the quantitation of specialized pro-resolving mediators in plasma and serum using ELISA and LC-MS/MS

Brendon Naicker, Vindya Ramanayake-Mudiyanselage, Tanya Maxey, Victoria J Tyrrell, James Horn, Paul D Kennedy, Daniel Tew, Jeff Johnson, Garret A FitzGerald, Robert C Murphy, Kirk Maxey, Valerie B O'Donnell und 1 weitere

Prostaglandins, Leukotrienes and Essential Fatty Acids · 2026-07 · 209 · 102731

DOI: 10.1016/j.plefa.2026.102731 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Prostaglandins, Leukotrienes and Essential Fatty Acids, 2026-07. Verfasst von Brendon Naicker und 12 weiteren Autor:innen. Beteiligte Einrichtung: Systems Immunity Research Institute School of Medicine Cardiff University, Cardiff, CF14 4XN, UK. Hauptthemen laut MEDLINE: Docosahexaenoic Acids, Liquid Chromatography-Mass Spectrometry, Oxylipins, Specialized Pro-Resolving Mediators. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UK Research and Innovation Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitation of oxylipins is generally performed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Researchers can also use commercial enzyme-linked immunosorbent assays (ELISAs), due to convenience or where access to instrumentation is limited. However, oxylipins are small molecules with many isomers and metabolites that are difficult to fully discriminate using ELISAs, with many potential sources of cross-reactivity. In this paper, the use of ELISAs for oxylipin analysis is compared with LC-MS/MS, with two specialized pro-resolving mediators (SPM) as examples. By reviewing the literature, we show that ELISAs report significantly higher levels of resolvin D1 (RvD1) and resolvin D2 (RvD2) than LC-MS/MS. Also, we show experimentally that in plasma and serum samples where these lipids were not detected using LC-MS/MS, a positive result could be obtained using ELISA, and that these signals increase with improper sample processing. In conclusion, while ELISA could be a useful technique for detecting the presence of oxylipins, positive signals need verification using LC-MS/MS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Docosahexaenoic AcidsLiquid Chromatography-Mass SpectrometryOxylipinsSpecialized Pro-Resolving MediatorsTandem Mass SpectrometryAnimalsHumansEnzyme-Linked Immunosorbent Assay

Stichwörter der Autor:innen

Enzyme-linked immunosorbent assayLiquid chromatography-mass spectrometryResolvin

Substanzen

Docosahexaenoic AcidsOxylipinsresolvin D1resolvin D2

Autor:innen und Institutionen

  • Systems Immunity Research Institute School of Medicine Cardiff University, Cardiff, CF14 4XN, UK.
  • Cayman Chemical Company, 1180 East Ellsworth Road, Ann Arbor, MI, 48116, USA.
  • Institute for Translational Medicine and Therapeutics Perelman School of Medicine University of Pennsylvania, Philadelphia, PA, 19104, USA.
  • University of Colorado Denver, Department of Pharmacology, Mail Stop 8303 RC1-South 12801 East 17th Avenue, Aurora, CO, 80045, USA.
  • Systems Immunity Research Institute School of Medicine Cardiff University, Cardiff, CF14 4XN, UK. Electronic address: o-donnellvb@cardiff.ac.uk.
  • Cayman Chemical Company, 1180 East Ellsworth Road, Ann Arbor, MI, 48116, USA. Electronic address: mgijon@caymanchem.com.

Förderung

  • UK Research and Innovation Medical Research Council

Zitieren

APA

Naicker, B., Ramanayake-Mudiyanselage, V., Maxey, T., Tyrrell, V. J., Horn, J., Kennedy, P. D., Tew, D., Johnson, J., FitzGerald, G. A., Murphy, R. C., Maxey, K., B O'Donnell, V., & Gijón, M. A. (2026). Comparing the quantitation of specialized pro-resolving mediators in plasma and serum using ELISA and LC-MS/MS. Prostaglandins, Leukotrienes and Essential Fatty Acids, 209, 102731. https://doi.org/10.1016/j.plefa.2026.102731

Vancouver

Naicker B, Ramanayake-Mudiyanselage V, Maxey T, Tyrrell VJ, Horn J, Kennedy PD, et al. Comparing the quantitation of specialized pro-resolving mediators in plasma and serum using ELISA and LC-MS/MS. Prostaglandins, Leukotrienes and Essential Fatty Acids. 2026;209:102731. doi:10.1016/j.plefa.2026.102731

BibTeX
@article{Naicker2026,
  author = {Naicker, Brendon and Ramanayake-Mudiyanselage, Vindya and Maxey, Tanya and Tyrrell, Victoria J and Horn, James and Kennedy, Paul D and Tew, Daniel and Johnson, Jeff and FitzGerald, Garret A and Murphy, Robert C and Maxey, Kirk and B O'Donnell, Valerie and Gijón, Miguel A},
  title = {Comparing the quantitation of specialized pro-resolving mediators in plasma and serum using ELISA and LC-MS/MS},
  journal = {Prostaglandins, Leukotrienes and Essential Fatty Acids},
  year = {2026},
  volume = {209},
  pages = {102731},
  doi = {10.1016/j.plefa.2026.102731}
}
Kostenlos starten →