The predictive value of conventional magnetic resonance imaging combined with intravoxel incoherent motion parameters for evaluating maternal and neonatal clinical outcomes in patients with placenta accreta spectrum disorders
Placenta · 2024
DOI: 10.1016/j.placenta.2024.04.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Placenta, 2024. Verfasst von Jin Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China. Hauptthemen laut MEDLINE: Placenta Accreta, Magnetic Resonance Imaging, Predictive Value of Tests. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: We aimed to identify factors predictive of adverse maternal and neonatal outcomes in patients with placenta accreta spectrum (PAS) disorders using magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) parameters. METHOD: Fifty-six normal singleton pregnancies at 33-39 weeks of gestation underwent MRI examination at 1.5 T. The IVIM parameters were obtained from the placenta. The correlation between the f value and postpartum hemorrhage (PPH) and between the f value and transfused units of red blood cells (RBCs) was estimated by linear regression. The correlation between various influencing factors (clinical risk factors, MRI features, and IVIM parameters) and poor outcomes was investigated using univariate and multivariate analyses. RESULT: The interobserver agreement ranged from fair to excellent (k = 0.30-0.88). Multivariate analyses showed that previous cesarean sections, low signal intensity bands on T2WI and the D value were independent risk factors for adverse outcomes. The combination of three risk factors demonstrated the highest AUC of 0.903, with a sensitivity and specificity of 73.10 % and 96.90 %, respectively. Last, f was positively correlated with PPH and units of RBCs transfused. DISCUSSION: Preoperative MRI features and IVIM parameters may be used to predict poor outcomes in patients with invasive placental disorders like PAS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China.
- Research Collaboration Team, Siemens Healthineers Ltd, Shanghai, China.
- Department of Obstetrics & Gynecology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China.
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China. Electronic address: xuanzhang1224@126.com.
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China. Electronic address: zm18901582106@126.com.
Zitieren
APA
Zhang, J., Kong, L., Qu, F., Chen, T., Zhou, X., Ge, Z., Jin, B., Zhang, X., & Zhao, M. (2024). The predictive value of conventional magnetic resonance imaging combined with intravoxel incoherent motion parameters for evaluating maternal and neonatal clinical outcomes in patients with placenta accreta spectrum disorders. Placenta. https://doi.org/10.1016/j.placenta.2024.04.007
Vancouver
Zhang J, Kong L, Qu F, Chen T, Zhou X, Ge Z, et al. The predictive value of conventional magnetic resonance imaging combined with intravoxel incoherent motion parameters for evaluating maternal and neonatal clinical outcomes in patients with placenta accreta spectrum disorders. Placenta. 2024. doi:10.1016/j.placenta.2024.04.007
BibTeX
@article{Zhang2024,
author = {Zhang, Jin and Kong, Lingnan and Qu, Feifei and Chen, Ting and Zhou, Xin and Ge, Zhiping and Jin, Bai and Zhang, Xuan and Zhao, Meng},
title = {The predictive value of conventional magnetic resonance imaging combined with intravoxel incoherent motion parameters for evaluating maternal and neonatal clinical outcomes in patients with placenta accreta spectrum disorders},
journal = {Placenta},
year = {2024},
doi = {10.1016/j.placenta.2024.04.007}
}
EUVIMED