EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Functional lung avoidance planning with combined ventilation-perfusion imaging versus individual functional imaging in lung cancer radiotherapy

Genta Michimata, Yujiro Nakajima, Tomoki Kimura, Nobuki Imano, Shinya Ito, Yukio Fujita, Naoki Tohyama

Physics and Imaging in Radiation Oncology · 2026-11 · 42 · 101118

DOI: 10.1016/j.phro.2026.101118 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2026-11. Verfasst von Genta Michimata und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, Komazawa University, 1-23-1 Komazawa, Setagaya-ku, Tokyo, 154-8525, Japan. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and purpose: Functional lung avoidance radiotherapy using four-dimensional computed tomography (4DCT) ventilation or single-photon emission computed tomography (SPECT) perfusion has been studied independently, however few studies have evaluated their combined use. The aim of this study was to examine whether integrating both modalities improved sparing of high functional lung (HFL) in non-small cell lung cancer (NSCLC). Materials and methods: Forty-seven patients with NSCLC underwent 4DCT ventilation and SPECT perfusion imaging. One patient was excluded, leaving 46 for analysis. Functional lung maps were segmented into high, middle, and low functional lung. Four volumetric-modulated arc therapy (VMAT) plans using 6 MV photons per patient were generated: anatomical (A), ventilation-guided (V), perfusion-guided (Q), and combined ventilation-perfusion-guided (VQ). Dose-volume and dose-function metrics were compared among plans. Correlations between tumor proximity to HFL and dose reduction were assessed.

Results

All function-guided plans significantly reduced HFL dose compared with A plans (p < 0.001). Among the function-guided plans, VQ plans yielded the lowest mean lung doses (MLDs) in high ventilated lung (VQ plans, 11.5 Gy; A plans, 12.4 Gy) and high perfused lung (VQ plans, 10.0 Gy; A plans, 11.1 Gy). Function-weighted metrics, including functional MLD, were also lowest with VQ plans, indicating improved functional lung sparing. Dose reduction correlated with tumor proximity to HFL, with the strongest associations observed at planning target volume expansions between 25 and 45 mm.

Conclusions

Integrating 4DCT ventilation and SPECT perfusion into radiotherapy planning improved functional lung sparing compared with anatomical or single-modality planning. Tumor proximity to functional lung influenced the magnitude of dose-volume benefits.

Schlagwörter

Stichwörter der Autor:innen

Image-guided radiation therapyLung perfusionLung ventilationNon-small-cell lung carcinomaSingle-photon emission computed tomographyTreatment planning

Autor:innen und Institutionen

  • Department of Radiological Sciences, Komazawa University, 1-23-1 Komazawa, Setagaya-ku, Tokyo, 154-8525, Japan.
  • Department of Radiation Oncology, International Medical Center, Saitama Medical University, 1397-1 Yamane, Hidaka-shi, Saitama 350-1298, Japan.
  • Department of Radiation Oncology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, 3-18-22 Honkomagome, Bunkyo-ku, Tokyo 113-8677, Japan.
  • Department of Radiation Oncology, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku-shi, Kochi 783-8505, Japan.
  • Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Michimata, G., Nakajima, Y., Kimura, T., Imano, N., Ito, S., Fujita, Y., & Tohyama, N. (2026). Functional lung avoidance planning with combined ventilation-perfusion imaging versus individual functional imaging in lung cancer radiotherapy. Physics and Imaging in Radiation Oncology, 42, 101118. https://doi.org/10.1016/j.phro.2026.101118

Vancouver

Michimata G, Nakajima Y, Kimura T, Imano N, Ito S, Fujita Y, et al. Functional lung avoidance planning with combined ventilation-perfusion imaging versus individual functional imaging in lung cancer radiotherapy. Physics and Imaging in Radiation Oncology. 2026;42:101118. doi:10.1016/j.phro.2026.101118

BibTeX
@article{Michimata2026,
  author = {Michimata, Genta and Nakajima, Yujiro and Kimura, Tomoki and Imano, Nobuki and Ito, Shinya and Fujita, Yukio and Tohyama, Naoki},
  title = {Functional lung avoidance planning with combined ventilation-perfusion imaging versus individual functional imaging in lung cancer radiotherapy},
  journal = {Physics and Imaging in Radiation Oncology},
  year = {2026},
  volume = {42},
  pages = {101118},
  doi = {10.1016/j.phro.2026.101118}
}
Kostenlos starten →