EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative evaluation of plan robustness in proton and photon radiotherapy in deep inspiration breath-hold for mediastinal lymphomas throughout the treatment course

Filip Hörberger, Marika Enmark, Karin M Andersson, Rebecka Ericsson Szecsenyi, Gracinda Johansson, Daniel Molin, Kenneth Wikström, Ingrid Kristensen, Anna Flejmer, Anneli Edvardsson

Physics and Imaging in Radiation Oncology · 2026-11 · 42 · 101111

DOI: 10.1016/j.phro.2026.101111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2026-11. Verfasst von Filip Hörberger und 9 weiteren Autor:innen. Beteiligte Einrichtung: Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Cancer Society.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and purpose: Proton therapy (PT) is sensitive to anatomical changes and setup uncertainties, which can compromise dose robustness in the treatment of mediastinal lymphoma, an issue less pronounced with photon-based radiotherapy. Variations in target position and size can potentially influence plan robustness. This study evaluated the robustness of pencil beam scanning (PBS) PT versus volumetric modulated arc therapy (VMAT) photon treatment plans across sub-target volumes and organs of interest (OOI) in deep inspiration breath-hold (DIBH) throughout treatment. Material and methods: Twenty-eight patients with upper mediastinal lymphoma treated with PBS-PT in DIBH were included. Clinically delivered PBS-PT plans were retrospectively compared with VMAT plans optimized per institutional standard-of-care. All plans were recalculated on weekly verification computed tomography images (vCTs) to assess target coverage and OOI doses. The internal target volumes (ITV) were subdivided into mediastinum, fossa supraclavicularis, neck, axilla and, along with OOIs, transferred from planning CTs to the vCTs.

Results

In the nominal plans, PBS-PT generally achieved lower OOI doses than VMAT, an advantage maintained on the vCTs. Both modalities demonstrated robust target coverage and OOI sparing. ITVTotal coverage fell below the set criterion (D98% > 95%) on at least one vCT for six patients with PBS-PT, but only one patient for VMAT. Pronounced deviations (D98% < 90%) occurred for two PBS-PT cases. Sub-target robustness was generally good.

Conclusions

Both PBS-PT and VMAT were robust for mediastinal lymphoma treatment in DIBH. In a proton-eligible DIBH cohort, PBS-PT provided superior OOI sparing, while VMAT demonstrated greater consistency in target coverage.

Schlagwörter

Stichwörter der Autor:innen

Deep inspiration breath-holdMediastinal lymphomasProton therapyRepeated verification CTsRobust optimizationVMAT

Autor:innen und Institutionen

  • Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
  • Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.
  • Department of Medical Physics, The Skandion Clinic, Uppsala, Sweden.
  • Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden.
  • Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden.
  • Department of Immunology, Genetics and Pathology: Cancer Immunotherapy, Uppsala University, Uppsala, Sweden.

Förderung

  • Swedish Cancer Society

Zitieren

APA

Hörberger, F., Enmark, M., Andersson, K. M., Szecsenyi, R. E., Johansson, G., Molin, D., Wikström, K., Kristensen, I., Flejmer, A., & Edvardsson, A. (2026). Comparative evaluation of plan robustness in proton and photon radiotherapy in deep inspiration breath-hold for mediastinal lymphomas throughout the treatment course. Physics and Imaging in Radiation Oncology, 42, 101111. https://doi.org/10.1016/j.phro.2026.101111

Vancouver

Hörberger F, Enmark M, Andersson KM, Szecsenyi RE, Johansson G, Molin D, et al. Comparative evaluation of plan robustness in proton and photon radiotherapy in deep inspiration breath-hold for mediastinal lymphomas throughout the treatment course. Physics and Imaging in Radiation Oncology. 2026;42:101111. doi:10.1016/j.phro.2026.101111

BibTeX
@article{Hrberger2026,
  author = {Hörberger, Filip and Enmark, Marika and Andersson, Karin M and Szecsenyi, Rebecka Ericsson and Johansson, Gracinda and Molin, Daniel and Wikström, Kenneth and Kristensen, Ingrid and Flejmer, Anna and Edvardsson, Anneli},
  title = {Comparative evaluation of plan robustness in proton and photon radiotherapy in deep inspiration breath-hold for mediastinal lymphomas throughout the treatment course},
  journal = {Physics and Imaging in Radiation Oncology},
  year = {2026},
  volume = {42},
  pages = {101111},
  doi = {10.1016/j.phro.2026.101111}
}
Kostenlos starten →