EBUS-TBNA and CryoEBUS of the mediastinal lymph node. One hundred seventy-eight cases. Validation of the WHO Reporting System for Lymph Node Cytopathology. Proposed CryoEBUS diagnostic flow chart and indications. The view of the interventional pathologist
Revista Española de Patología · 2025
DOI: 10.1016/j.patol.2024.100799 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Revista Española de Patología, 2025. Verfasst von Luis Manuel Fernández Fernández und 13 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitario Central de Asturias, Pathology Department, Oviedo, Spain. Hauptthemen laut MEDLINE: Lymph Nodes, Endoscopic Ultrasound-Guided Fine Needle Aspiration. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
INTRODUCTION: Microscopic assessment is essential in the study of mediastinal lymph nodes. Obtaining cytological samples through Endobronchial Ultrasound TransBronchial Needle Aspiration (EBUS-TBNA) has long been considered the gold standard procedure. The implementation of the World Health Organization (WHO) Reporting System for Lymph Node Cytopathology, along with the advancement of the CryoEBUS lymph node technique, has enhanced and refined diagnostic accuracy in this field. MATERIALS AND METHOD: During a two-year period, cases involving the parallel performance of EBUS-TBNA and CryoEBUS specimen collection were quantified. The implementation of the WHO Reporting System allowed for the comparison of diagnostic yield between cytological and CryoEBUS tissue samples. RESULTS: A total of 178 EBUS-TBNA and CryoEBUS procedures were conducted, with a mean patient age of 63 years and a male predominance of 72.5%. Lymph node station 7 was the most sampled site, accounting for 38.76% of cases. Category V - malignant was the most common cytological diagnosis, representing 50% of cases, while 46.62% of CryoEBUS samples were malignant. The Pearson correlation coefficient between the two methods was calculated at 0.99. CONCLUSIONS: The combined implementation of the WHO Reporting System for Lymph Node Cytopathology and the simultaneous use of CryoEBUS resulted in enhanced performance and diagnostic accuracy, reducing non-diagnostic samples to less than 3%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hospital Universitario Central de Asturias, Pathology Department, Oviedo, Spain.
- Hospital Universitario Central de Asturias, Pathology Department, Universidad de Oviedo, Oviedo, Spain.
- Hospital Universitario Central de Asturias, Pneumology Department, Oviedo, Spain.
- Hospital Universitario del Henares, Pathology Department, Madrid, Spain.
- Hospital Universitario de la Princesa, Department of Anaesthesiology and Surgical Critical Care, Madrid, Spain.
- Pathology Department, Hospital Universitario Marqués de Valdecilla, Santander, Spain.
Zitieren
APA
Fernández Fernández, L. M., González Gutiérrez, M. P., Rubiera, M., Berrios Hernández, M. L., González Rodríguez, C., Ariza Prota, M., Pérez Fontán, J. F., Villar Zarra, K., Nieves-Alonso, J., Gómez-Román, J. J., Dolores Lozano, M., Pérez-Machado, M. Á., Colado Varela, E., & Torres-Rivas, H. E. (2025). EBUS-TBNA and CryoEBUS of the mediastinal lymph node. One hundred seventy-eight cases. Validation of the WHO Reporting System for Lymph Node Cytopathology. Proposed CryoEBUS diagnostic flow chart and indications. The view of the interventional pathologist. Revista Española de Patología. https://doi.org/10.1016/j.patol.2024.100799
Vancouver
Fernández Fernández LM, González Gutiérrez MP, Rubiera M, Berrios Hernández ML, González Rodríguez C, Ariza Prota M, et al. EBUS-TBNA and CryoEBUS of the mediastinal lymph node. One hundred seventy-eight cases. Validation of the WHO Reporting System for Lymph Node Cytopathology. Proposed CryoEBUS diagnostic flow chart and indications. The view of the interventional pathologist. Revista Española de Patología. 2025. doi:10.1016/j.patol.2024.100799
BibTeX
@article{FernndezFernndez2025,
author = {Fernández Fernández, Luis Manuel and González Gutiérrez, María de la Paz and Rubiera, Miriam and Berrios Hernández, Mario Luis and González Rodríguez, Clara and Ariza Prota, Miguel and Pérez Fontán, José Fernando and Villar Zarra, Karen and Nieves-Alonso, Jesús and Gómez-Román, José Javier and Dolores Lozano, María and Pérez-Machado, Miguel Ángel and Colado Varela, Enrique and Torres-Rivas, Héctor-Enrique},
title = {EBUS-TBNA and CryoEBUS of the mediastinal lymph node. One hundred seventy-eight cases. Validation of the WHO Reporting System for Lymph Node Cytopathology. Proposed CryoEBUS diagnostic flow chart and indications. The view of the interventional pathologist},
journal = {Revista Española de Patología},
year = {2025},
doi = {10.1016/j.patol.2024.100799}
}
EUVIMED